background image

P. I. E. INEL Sp. z o. o., ul. Mostowa 1, 80-778 Gdańsk, [email protected]                                                                                   www.inel.gda.pl

 

 

If  the  motor  is  transferred  to  another  roller  blind,  reset  it  to 
factory settings (section 6). 

6.  RETURN TO FACTORY MODE 

 

Press the ▲ and ▼ buttons on the remote at the same time, the 
motor will make a short up-down movement, then press STOP. 
The  motor  will  make  another  short  up-down  movement.  
Perform this operation 4 times. 

 

7.  TROUBLESHOOTING 

TROUBLESHOOTING 

 
Problem:

 

The motor does not react to commands 

Cause:

  Thermal cut-out was activated 

Solution:

 

Wait for 10-20 minutes 

 

Problem:

 

The motor revolves in the direction opposite to 
the input from the remote control 

Solution:

 

Invert the movement direction of the motor, 

section 4. 
 

Problem:

 

The motor stops on its own 

Cause:

 

The curtain is blocked in the guides 

Solution:

 

Check the roller blind guides and curtain slats 

 

8.  MOTOR SELECTION TABLE 

 

Torque 

Diameter 

Roller blind length 

 

 

1.5 m 

2.0 m 

2.5 m 

3.0 m 

10 Nm 

40 mm 

20 kg 

19 kg 

18 kg 

17 kg 

20 Nm 

60 mm 

42 kg 

40 kg 

38 kg 

36 kg 