P. I. E. INEL Sp. z o. o., ul. Mostowa 1, 80-778 Gdańsk, [email protected] www.inel.gda.pl
If the motor is transferred to another roller blind, reset it to
factory settings (section 6).
6. RETURN TO FACTORY MODE
Press the ▲ and ▼ buttons on the remote at the same time, the
motor will make a short up-down movement, then press STOP.
The motor will make another short up-down movement.
Perform this operation 4 times.
7. TROUBLESHOOTING
TROUBLESHOOTING
Problem:
The motor does not react to commands
Cause:
Thermal cut-out was activated
Solution:
Wait for 10-20 minutes
Problem:
The motor revolves in the direction opposite to
the input from the remote control
Solution:
Invert the movement direction of the motor,
section 4.
Problem:
The motor stops on its own
Cause:
The curtain is blocked in the guides
Solution:
Check the roller blind guides and curtain slats
8. MOTOR SELECTION TABLE
Torque
Diameter
Roller blind length
1.5 m
2.0 m
2.5 m
3.0 m
10 Nm
40 mm
20 kg
19 kg
18 kg
17 kg
20 Nm
60 mm
42 kg
40 kg
38 kg
36 kg