background image

ST-0P  controllers

  can  be  used  to  control  roller  shutters  and  roller  blinds  (ST-0PZ  version).  For  flush-mounting  in a 

double depth back box. All controllers feature stand-by function, i.e. short press of any key on the manual switch will 
activate an open/close cycle of the roller shutter (factory set voltage supply time is 100 s.). The function is available for 
a switch connected to “MANUAL” terminal only. For bus control, the voltage supply time corresponds to the time the 
signal is fed to the bus. A group of ST-0P controllers can be controlled by any roller shutter controller available on the 
market. 

Wiring diagram - ST-0P controller

 

  

1.Connect the roller blind switch to J4 terminal strip with 3 terminals: 
  

Terminal 1 to UP key      

  

Terminal 2 to common  

  

Terminal 3 to DOWN key. 

2. Connect the motor to J2 terminal strip with 4 terminals: 
  

Terminal 1 to UP conductor      

  

Terminal 2 to common conductor  

  

Terminal 3 to DOWN conductor 

  

Terminal 4 to protective conductor 

3. Connect the following to J1 terminal strip with 5 terminals: 
  

Terminal 5 to UP control voltage 

  

Terminal 4 to DOWN control voltage 

  

Terminal 3 to L1 conductor (230V supply voltage) 

  

Terminal 2 to N conductor (230V supply voltage) 

  

Terminal 1 to PE protective conductor (230V supply voltage)  

Connecting ST-0P controllers in a sub-group

 

To create a sub-group of ST-05 controllers, all controllers must be connected to a 5 terminal bus, motors and manual 
switches. 

 

Connecting ST-0P controller to a sub-group

 

The  sub-group  can  be  controlled  with  a  single  manual  switch,  provided  that  an  additional  controller,  that  does  not 
control the motor and controls other controllers via a bus is installed. The additional controller is connected differently 
than the other controllers. Connect L1, N and PE conductor to the terminals. Connect UP and DOWN motor winding 
control outputs to G and D bus conductors. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

Roller blind control (version ST-0PZ)

 

Press  the  manual  UP  or  DOWN  switch  for  approx.  1  second,  the  roller  blind  will  open  or  close  until  the  motor  is 
deactivated by one of the limit switches. Select DOWN to close the roller blind with the slats closed. Hold the manual 
switch for 1 second to adjust the slats - the slat position can be adjusted stepwise in both directions until fully closed. 

CONTROL 
SUB-GROUP 

 

SUB-GROUP 