ST-0P controllers
can be used to control roller shutters and roller blinds (ST-0PZ version). For flush-mounting in a
double depth back box. All controllers feature stand-by function, i.e. short press of any key on the manual switch will
activate an open/close cycle of the roller shutter (factory set voltage supply time is 100 s.). The function is available for
a switch connected to “MANUAL” terminal only. For bus control, the voltage supply time corresponds to the time the
signal is fed to the bus. A group of ST-0P controllers can be controlled by any roller shutter controller available on the
market.
Wiring diagram - ST-0P controller
1.Connect the roller blind switch to J4 terminal strip with 3 terminals:
Terminal 1 to UP key
Terminal 2 to common
Terminal 3 to DOWN key.
2. Connect the motor to J2 terminal strip with 4 terminals:
Terminal 1 to UP conductor
Terminal 2 to common conductor
Terminal 3 to DOWN conductor
Terminal 4 to protective conductor
3. Connect the following to J1 terminal strip with 5 terminals:
Terminal 5 to UP control voltage
Terminal 4 to DOWN control voltage
Terminal 3 to L1 conductor (230V supply voltage)
Terminal 2 to N conductor (230V supply voltage)
Terminal 1 to PE protective conductor (230V supply voltage)
Connecting ST-0P controllers in a sub-group
To create a sub-group of ST-05 controllers, all controllers must be connected to a 5 terminal bus, motors and manual
switches.
Connecting ST-0P controller to a sub-group
The sub-group can be controlled with a single manual switch, provided that an additional controller, that does not
control the motor and controls other controllers via a bus is installed. The additional controller is connected differently
than the other controllers. Connect L1, N and PE conductor to the terminals. Connect UP and DOWN motor winding
control outputs to G and D bus conductors.
Roller blind control (version ST-0PZ)
Press the manual UP or DOWN switch for approx. 1 second, the roller blind will open or close until the motor is
deactivated by one of the limit switches. Select DOWN to close the roller blind with the slats closed. Hold the manual
switch for 1 second to adjust the slats - the slat position can be adjusted stepwise in both directions until fully closed.
CONTROL
SUB-GROUP
SUB-GROUP