Przedsiębiorstwo Informatyczno-Elektroniczne INEL Sp. z o.o., ul. Mostowa 1, 80-778 Gdańsk, [email protected] www.inel.gda.pl
press the key (STOP) on the remote control – the drive
makes 2 long confirmatory up-down movements
Note: the end positions will be erased when the direction is
changed.
5
Setting of end positions (EP)
Manual EP setting is not necessary, as the drive can set it
automatically. For this purpose, 3 cycles of full opening / closing of
the roller shutter are required. The drive has an overload detection
function; after stopping 3 times at an obstacle (parapet, stopwatch) in
the same place, it sets a zone of increased sensitivity there.
Subsequent stops in this zone will occur with greater sensitivity – as
you enter the zone, the motor slows down, gently reaches the
obstacle and stops.
After moving the drive to another window or after changing the length
of the roller shutter, it is enough to make 3 cycles of closing/opening
the roller shutter for the drive to set the new end positions
The drive starts at 100% when moving downwards, and at 50%
when moving upwards and accelerates to 100% after 2 s
The manual setting of the EP is described below.
The order in which the EPs are set is irrelevant; you can set both EPs,
only one of them or not set an EP at all.
The EPs cannot be set too close together; the drive will make a short
up-and-down movement when attempting to do so.
5.1
Setting the upper end position (UEP)
To set the upper end position (UEP):
set the roller shutter to the desired UEP (with the
∧
,
∨
,
(STOP) keys on the remote control
press simultaneously the keys
∧
and
∨
on the remote
control - the drive makes a short up-down movement
press the key
∧
on the remote control – the drive makes a
long up-down movement
press simultaneously the keys
∧
and
∨
on the remote
control - the drive makes a short up-down movement
press the key
∧
on the remote control – the drive makes 2
long up-down movements – the UEP has been set
5.2
Setting the lower end position (LEP)
To set the lower end position (LEP):
set the roller shutter to the desired LEP (with the
∧
,
∨
,
(STOP) keys on the remote control
press simultaneously the keys
∧
and
∨
on the remote
control - the drive makes a short up-down movement
press the key
∧
on the remote control – the drive makes a
long up-down movement
press simultaneously the keys
∧
and
∨
on the remote
control - the drive makes a short up-down movement
press the key
∧
on the remote control – the drive makes 2
long up-down movements – the LEP has been set
5.3
Erasing end positions (EP)
To erase end positions (EP): execute
twice
the procedure for
reversing the direction of rotation
press simultaneously the keys
∧
and
∨
on the remote
control – the drive makes a short up-down movement
press the key (STOP) on the remote control – the drive
makes a long up-down movement
press simultaneously the keys
∧
and
∨
on the remote
control – the drive makes a short up-down movement
press the key (STOP) button on the remote control – the
drive makes 2 long up-down movements
repeat the above steps
6
Operating instructions
6.1
Battery
The manufacturer supplies the drive with a charged battery. Once the
drive is installed, the battery is recharged with electricity from the solar
panel.
If there is a long period between purchase and installation of the drive,
the battery should be charged using a charger (sold separately by the
manufacturer). The charger should be connected to the drive in place
of the solar panel. The time to full charge is approximately 8 hours.
If the charge level is too low, the drive stops and makes 2 short up-
down movements when attempting to start.
When the need to charge the battery with the charger occurs too
frequently, check the condition of the solar panel. If the panel is clean
and sunlight reaches it unobstructed, the battery is probably worn
down.
6.2
Solar panel
The solar panel must be kept clean. Use clean water and a soft cloth
for cleaning.
Do not allow leaves or snow to cover the panel.
The direction of
rotation has been
changed
LEP set up
EP erased
UEP set up