Appendix C - Using Non-IDC Motors with the Impulse
C-2
Custom or User-Defined Motors
This section applies to users of non-IDC motors or those who would like to modify an existing motor
file.
Note:
All motor characteristics must be entered in the text input boxes
before the
Advanced
tuning
feature will be available.
• Click on the
Add Custom Motor
button and the
Motor Editor
will appear.
• Enter a file name for your custom motor in the
Motor File Name
text-entry box. File
names may be up to eight (8) characters in length (all keyboard characters are valid). This
also applies if you are editing an existing IDC motor file.
• Enter the Mechanical characteristics of your custom motor.
Rotor Inertia
in kg-m
2
Tooth Count
in number of teeth on the rotor
• Enter the Electrical characteristics of your custom motor.
Operating Current
is the current-magnitude command to the drive in Amps (it is not
RMS). The value entered represents the peak amplitude of the phase currents.
Saturation Current
(in Amps) is critical for the implementation of the Impulse’s exclusive
Open Loop Stall Detect
TM
feature. Saturation Current has been pre-configured under labo-
ratory conditions for IDC motors, but cannot be accurately determined in the field for cus-
tom motors. If an incorrect Saturation Current is entered, the Open Loop Stall Detect
(OLSD) feature may be ineffective. Contact your distributor or IDC Applications Engi-
neering for assistance.
In the absence of an accurate Saturation Current, you have three options: 1) enter an esti-
mated value based on the characteristics of a similar type of motor, 2) enter the same value
as the Operating Current, or 3) disable the OLSD feature (see Application Developer
Setup
> Axis > Advanced
tab to disable Stall Detection).
Rated Torque
is the rated torque (N-m) of the manufacturer’s motor at the rated current.
This may be set to zero (0) if unknown and it will have no effect on the drive. This number
is used by the Speed Torque Curve utility and is numerically equal to the quotient of the
manufacturer’s specified 2-phase resting torque divided by the specified current (Nm/
Amp). Always convert torque to Newton-meters.
Rated Current
is the amplitude of the current generated when the windings are shorted and
the motor’s rotor is back-driven (forced to move). This short-circuit current is of constant
amplitude for speeds above 2 RPS. Determining
Rated Current
in the field is very diffi-
Содержание Impulse PCW-5181
Страница 2: ......
Страница 4: ......
Страница 8: ...Chapter 1 Overview 1 2 This page intentionally left blank...
Страница 10: ...Chapter 2 Shipping Contents 2 2 This page intentionally left blank...
Страница 24: ...Chapter 3 Connecting and Installing Your Impulse 3 14 This page intentionally left blank...
Страница 52: ...Chapter 4 Configuring Impulse with Application Developer 4 28 This page intentionally left blank...
Страница 90: ...Chapter 6 Hardware Reference 6 14 This page intentionally left blank...
Страница 94: ...Chapter 7 Troubleshooting Your Impulse 7 4 This page intentionally left blank...
Страница 98: ...Appendix A Recommended Wiring Practices A 2...
Страница 119: ...Do Not Print This Page Inserted as Placeholder...