IDS 410/422 User's Manual
14
Press the (+) or (-) key until the second from the right most digit is 7. Press the
item
key to
advance to the next digit. Press the (+) or (-) key until the digit is 3 (display = 73). Press the
enter
key. Press the (+) or (-) keys to change the mode number. Press the ENTER key to store
the displayed mode number. If you changed the mode number the display will prompt "rS Fnx"
where 'x' is the new mode number. Press the
enter
key again. If you did NOT change the mode
number then the "rS Fnx" message will NOT be displayed and the additional data will not be
prompted for.
Press the
clear
key (when "CFG 73" is displayed ) exit configuration setup.
Modes of Operation
Set configuration parameter (CFG 73) to one of the following modes:
0 – Normal/Basic weighing & printing
1 - Print weight and Total (Numbered weights)
2 – Auto Print weight & Total (Numbered weights)
3 – Auto Axle Weigh (Short Scale)
4 - Auto-Axle Weigh (Long Scales)
5 - Peak Hold
6 - Over / Under Checkweigh
7 – Fill to Target Weight, Setpoint, Bulkweigh
Normal Mode/Basic Weigh & Print (Mode 0)
The Normal Mode provides push button ZERO, push-button TARE, view GROSS/NET toggle,
units (lb/kg) toggle, and print functions.
ZERO
Press the ZERO key to zero the scale. The following conditions must be met for the ZERO key
to function:
•
The gross weight is within the configured zero range: 1% to 100% of full scale.
•
The scale is stable (no motion).
TARE
Press the TARE key. The IDS 410/422 reads the weight on the scale and stores it in the tare
register. The IDS 410/422 switches to NET mode and displays the net weight. If the gross
weight on the scale is zero (0), the tare register is set to 0 and the mode switches to GROSS
display mode.
Содержание IDS 410