Index Braille
Page 13
Index 4X4 PRO
January 2000
Version 1.20
5.3
Change Setup
This is an example of a command sequence that changes the item
VOLUME
in group
OPTION
to highest
level.
1. Press
SETUP
.
2. Press
GROUP
until the embosser echoes “Option”.
3. Press
ITEM
until the embosser echoes “Volume”.
4. Press
VALUE
until the embosser echoes “five”.
5. Press
SETUP
to save.
5.3.1
Braille code
In this group the following items can be changed; Language, Computer or Literary (Grade 1) Braille, 6
or 8 dot Braille in computer Braille, and with or without capital prefix in Literary (Grade 1) Braille.
When a user defined Braille table is used, it can be changed to all combinations between literary and
computer Braille with no system limitations.
5.3.2
Serial communication
In this group all serial communication parameters can be changed.
Baud rate
300/600/1200/2400/4800/9600.
Serial data
7/8.
Parity
Odd/Even/None.
Stop Bit
1/2.
Handshake
Hardware/Software.
5.3.3
Page layout
Page layout contains the following options:
Characters per line
23-38
Top Margin
0-3 lines height
Bottom Margin
0-3 characters width
Print mode
Normal/Reformatted.
Page number
On/Off.
Page width
100-297 mm
Page length
110-500 mm
Number of page
1,2 or 4
5.3.3.1
Characters per line
When 4X4 measures the paper, it automatically calculates and sets the number of characters per line
margin. With Characters per line you can change the value of the number of characters per line. When
changing the value, it will effect only the width of the binding margin.
5.3.3.2
Print mode
With the option print mode, you can select between normal and reformatted printout.
5.3.3.3
Page number
With the option page number, you can select page numbering - On/Off.
The page number will be printed in the upper right corner of the page.