Precautions and tips

!

 This appliance has been designed and

manufactured in compliance with international safety

standards. The following warnings are provided for

safety reasons and must be read carefully.

General safety

•

This manual is for a class 3 built-in cooktop.

•

Gas appliances require regular air exchange to

ensure trouble-free performance. When

installing the cooker, follow the instructions

provided in the paragraph on “Positioning” the

appliance.

•

These instructions are only valid for the

countries the symbols for which appear on the

manual and the serial plate.

• This appliance was designed for domestic use

inside the home and is not intended for commercial

or industrial use.

• The appliance must not be installed outdoors, even

in covered areas. It is extremely dangerous to leave

the appliance exposed to rain and storms.

• Do not touch the appliance with bare feet or with

wet or damp hands and feet.

• The appliance must be used by adults only, to cook

food according to the instructions in this manual.

Do not use the hob as a worktop or chopping

board.

• Ensure that power supply cables of other electrical

appliances do not come into contact with the hot

parts of the hob.

• The openings and slots used for ventilation and

heat dispersion must never be covered.

• Make sure the knobs are in the “

”/”

¡

” position when

the appliance is not in use.

• When unplugging the appliance always pull the plug

from the mains socket, do not pull on the cable.

• Never carry out any cleaning or maintenance work

without having unplugged the plug from the mains.

• Always make sure pan handles are turned towards

the centre of the hob in order to avoid accidental

burns.

• Avoid closing the cover (if present) while the gas

burners and electric plates are still warm.

• Do not use cookware with uneven or deformed

bottoms.

Disposal

• When disposing of packaging material: observe

local legislation so that the packaging may be

reused.

• When disposing of your old appliance: contact your

Local Organisation in charge of waste disposal.

• Make the appliance unusable by cutting off the

electrical cable before disposal.

Содержание PI 640 A GB

Страница 1: ...acteristic of the burners and nozzles Description of the appliance 7 Overall view Start up and use 8 Practical Advise on Using the Burners Precautions and tips 9 General safety Disposal Maintenance and care 10 Switching the appliance off Cleaning the appliance Greasing the Taps Assistance 11 Operating Instructions English 1 GB ...

Страница 2: ... fuel burning appliances in the same room B S 5440 Part 2 Current Edition should be consulted to determine the requisite air vent requirements Fitting the appliance The appliance can be installed next to furniture units which are no taller than the top of the cooker hob The wall in direct contact with the back panel of the cooker must be made of non flammable material During operation the back pan...

Страница 3: ... must be placed between the appliance and the mains with a minimum opening between the contacts of 3 mm in compliance with current safety codes the earthing wire must not be interrupted by the switch The power supply cord must be positioned so that it does not reach a temperature in excess of 50 C above room temperature at any point The installer must ensure that the correct electrical connection ...

Страница 4: ...askets that comply with current safety codes The maximum length of the flexible pipes must not exceed 2000 mm Once the connection has been made ensure that the flexible metal tube does not touch any moving parts and is not crushed Check the Seal Once the appliance has been installed make sure all the connections are properly sealed using a soapy water solution Never use a flame Adapting the Cookto...

Страница 5: ... G30 575 g h G31 Electrical section voltage 220 240V 50 60Hz This appliance conforms to the following European Economic Community directives 73 23 EEC of 19 02 73 Low Voltage and subsequent amendments 89 336 EEC of 03 05 89 Electromagnetic Compatibility and subsequent amendments 90 396 EEC of 29 06 90 Gas and subsequent modifications 93 68 EEC of 22 07 93 and subsequent amendments 1 The values in ...

Страница 6: ...0 3 00 0 70 41 87 218 214 128 286 Semi Fast S 75 1 90 0 40 30 70 138 136 104 181 Auxiliary A 51 1 00 0 40 30 52 73 71 76 95 Triple Crown TC 130 3 25 1 30 57 91 236 232 133 309 Supply Pressures Nominal mbar Minimum mbar Maximum mbar 28 30 20 35 37 25 45 20 17 25 At 15 C and 1013 mbar dry gas Propane P C S 50 37 MJ kg Butane P C S 49 47 MJ kg Natural P C S 37 78 MJ m3 S S A R S S A TC PI 640 A GB PI...

Страница 7: ...GB 7 Description of the appliance Overall view Gas Burners Support Grid for Cookware Control Knobs for Gas Burners Ignition Button for Gas Burners Ignitor for Gas Burners ...

Страница 8: ...and then the corresponding knob pushed all the way in and turned in the counter clockwise direction to the High setting If the burner accidently goes out turn off the gas with the control knob and try to light it again after waiting at least 1 minute To turn off a burner turn the knob in the clockwise direction until it stops it should be on the setting Practical Advise on Using the Burners For be...

Страница 9: ...d by adults only to cook food according to the instructions in this manual Do not use the hob as a worktop or chopping board Ensure that power supply cables of other electrical appliances do not come into contact with the hot parts of the hob The openings and slots used for ventilation and heat dispersion must never be covered Make sure the knobs are in the position when the appliance is not in us...

Страница 10: ...are to eliminate any scale In the hob equipped with automatic lighting the terminal part of the electronic instant lighting devices should be cleaned frequently and the gas outlet holes on the flame spreaders should be checked to make sure they are free of any obstructions Stainless steel may become marked if it comes into contact with very hard water or harsh detergents containing phosphorous for...

Страница 11: ...ugh to activate the safety device The gas holes are not clogged in the area corresponding to the safety device The burner does not remain on when set to Low Check to make sure that The gas holes are not clogged There are no draughts near the cooking surface The minimum has been adjusted correctly see the section entitled Minimum Regulation The cookware is not stable Check to make sure that The bot...

Страница 12: ...12 GB 10 2004 195045883 00 XEROX BUSINESS SERVICES ...

Отзывы: