a
ssis
T
an
CE
E
n
0
Service Manual
P0055 coffee Machine - 2006
Edition
2006.08.28
Language
english
level M3: Tests on coffee grinder
This level allows the service engineer to check
operation of the coffee grinder.
The first line shows a description of the level and
a space for analog information, if present (red
circle).
The second line shows whether or not the load is
active (blue circle). Additional information is shown
in the red circle and the flashing “X” (green circle).
When the coffee grinder is operating (up button) the
speed is shown in rpm (red circle ) and the “X” flashes
(green circle).
“v” can show one of the Aroma levels: 0 - 1 - 2 (see
heading 2.3.2). The value can be edited with the
doWn button and saved by pressing ok.
If the value has been edited but not saved the
“*” symbol will be displayed at the end of the second
line. When the value is saved, the “*” symbol
disappears.
level M4: Jumpers
In this section you can check the jumper configuration,
i.e. the presence or absence of certain jumpers.
figure 1. e.g.: all jumpers present
figure 2. e.g.: only jumper Jp27 present
note: the presence of Jp27 is required for the
plumbed-in configuration: in this case the “water
connection” option appears automatically in the
user menu, although it must still be activated if it is
to be used.
how to quit Test mode.
Switch off the machine and then switch it on again.