Indesit P 640 TC (IX) GB Скачать руководство пользователя страница 8

6

Electrical connection
THE APPLIANCE MUST BE EARTHED
The hob is designed to work with alternating current at the
supply voltage and frequency indicated on the rating plate
(situated under the hob or at the end of the instruction
booklet). Make sure that the local supply voltage corresponds
to the voltage indicated on the rating plate.

Connecting the supply cable to the mains electricity
supply
For models supplied without a plug, fit a standard plug,
suitable for the load indicated on the rating plate, onto the
cable and connect to a suitable socket.
To connect directly to the mains supply, a double-pole switch
with a contact separation of at least 3 mm suitable for the
load and complying with current standards and regulations,
must be fitted between the appliance and the mains supply
outlet. The yellow-green earth wire must not be interrupted
by the switch. The supply cable must be in such a position
that no part of it can reach a temperature of 50°C above
room temperature. For installation above a built-under oven,
the hob and the oven must be connected separately to the
electricity supply both for safety reasons and for easy removal
of the oven if necessary. Do not use adapters or shunts as
they could cause heating or burning. Before connecting to
the power supply, make sure that:
• the limiter valve and the domestic system can withstand

the load from the appliance (see rating plate);

Instructions for the installer

• the supply system is efficiently earthed according to

standards and laws in force;

• the socket or double-pole switch are easily accessible when

the appliance is installed.

Important: the wires in the mains lead are coloured in
accordance with the following code:
Green & Yellow

- Earth

Blue

- Neutral

Brown

- Live

As the colours of the wires in the mains lead may not
correspond with the coloured markings identifying the
terminals in your plug, proceed as follows:
Connect the Green & Yellow wire to terminal marked “E” or

 or coloured Green or Green & Yellow.

Connect the Brown wire to the terminal marked “L” or
coloured Red.
Connect the Blue wire to the terminal marked “N” or coloured
Black.

FAILURE TO OBSERVE THE ACCIDENT-PREVENTION
REGULATIONS RELIEVES THE MANUFACTURER OF ALL
LIABILITY.

Replacing the cable
Use a rubber cable of the type H05RR-F with a cross section
3 x 0.75 mm².
The yellow-green earth wire must be 2-3 cm longer than the
other wires.

Burners and nozzles characteristics

*

At 15°C and 1013 mbar-dry gas

**

Propane G31

 H.s. = 50,37 MJ/kg

***

Butane G30            H.s. = 49,47 MJ/kg
Natural gas G20

 H.s. = 37,78 MJ/m

3

1

e

l

b

a

T

s

a

g

d

i

u

q

i

L

s

a

g

l

a

r

u

t

a

N

r

e

n

r

u

B

r

e

t

e

m

a

i

D

)

m

m

(

r

e

w

o

p

l

a

m

r

e

h

T

)

*

.

s

.

H

(

W

k

s

s

a

p

-

y

B

0

0

1

/

1

)

m

m

(

r

o

t

c

e

j

n

I

0

0

1

/

1

)

m

m

(

*

w

o

l

F

h

/

g

r

o

t

c

e

j

n

I

0

0

1

/

1

)

m

m

(

*

w

o

l

F

h

/

l

.

n

i

m

o

N

.

c

u

d

e

R

0

3

G

*

*

*

1

3

G

*

*

0

2

G

C

d

i

p

a

r

-

i

m

e

S

5

7

5

6

.

1

4

.

0

0

3

4

6

0

2

1

8

1

1

6

9

7

5

1

A

y

r

a

il

i

x

u

A

5

5

0

0

.

1

3

.

0

7

2

0

5

3

7

1

7

1

7

5

9

E

g

n

i

r

e

l

p

i

r

T

0

3

1

5

2

.

3

3

.

1

7

5

1

9

6

3

2

2

3

2

4

2

1

9

0

3

y

l

p

p

u

S

e

r

u

s

s

e

r

p

)

r

a

b

m

(

l

a

n

i

m

o

N

0

3

-

8

2

7

3

0

2

This appliance conforms with the following European
Economic Community directives:
-

73/23/EEC of 19/02/73 (Low Voltage) and subsequent
modifications;

-

89/336/EEC of 03/05/89 (Electromagnetic Compatibility)
and subsequent modifications;

-

90/396/EEC of 29/06/90 (Gas) and subsequent
modifications;

-

93/68/EEC of 22/07/93 and subsequent modifications.

Содержание P 640 TC (IX) GB

Страница 1: ...P 640 TC IX GB Built in hobs Instructions for use and installation...

Страница 2: ...Built in hobs Instructions for use and installation...

Страница 3: ...pushing the button marked with the symbol Checking that the flame is stable If it is not repeat the operation For minimum power turn the knob towards the low flame symbol Intermediate positions are p...

Страница 4: ...ing abrasive powders or corrosive substances which could ruin them The removable parts of the burners should be washed frequently with warm water and soap making sure to remove caked on substance Chec...

Страница 5: ...r supply cord In the case of a breakdown or malfunction ask for original spare parts It is recommended that you follow the guidelines below Only use the appliance to cook food avoiding all other uses...

Страница 6: ...ncreased in relation to its maximum performance The electric fan should have a sufficient capacity to guarantee an hourly exchange of air equal to 3 5 times the volume of the kitchen Prolonged intensi...

Страница 7: ...internal connections and the taps for leaks using a soapy solution never a flame Also check that the connecting pipe cannot come into contact with moving parts which could damage or crush it Make sure...

Страница 8: ...is installed Important the wires in the mains lead are coloured in accordance with the following code Green Yellow Earth Blue Neutral Brown Live As the colours of the wires in the mains lead may not...

Страница 9: ......

Страница 10: ......

Страница 11: ......

Страница 12: ...09 01 Cod 195032114 01 Merloni Elettrodomestici Viale Aristide Merloni 47 60044 Fabriano Italy Tel 39 0732 6611 Fax 39 0732 662501 www merloni com...

Отзывы: