TECHNICAL DATA
DIMENSIONS
Height
900 - 915mm
Width
1000mm
Depth
600mm (excluding door handles)
GENERAL
Gas connection
Rp
1
/
2
(
1
/
2
” BSP female)
Pressure test point
Hotplate burner injector
Gas rate adjustment
None
Aeration adjustment
None
Electrical connection
230/240V a.c. 50Hz.
Total electrical heat input
7.4 kW
HEAT INPUT
HEAT
INPUT
BURNER
INJECTOR
HEAT INPUT
INJECTOR
Cat II
2H3+
G20 at 20 mbar
Cat II
2H3+
G30 at 28 - 30 mbar
G31 at 37 mbar
240V a.c.
2.7 kW
GRILL
2.5 kW
Left OVEN
2.0 kW
Right OVEN
2.7 kW
2.7 kW (195g/hr)
HOTPLATE
outer front left
125
2.0 kW
HOTPLATE
outer rear left
102
1.8 kW (130g/hr)
82
65
1.0 kW
1.0 kW (75g/hr)
HOTPLATE
inner rear left
72
2.0 kW
HOTPLATE
inner front left
102
1.8 kW (130g/hr)
50
65
1.0 kW
1.0 kW (75g/hr)
HOTPLATE outer
rear right
72
2.0 kW
HOTPLATE outer
front right
102
1.8 kW (130g/hr)
50
65
3.0 kW
2.8 kW (205g/hr)
HOTPLATE
inner front right
128
2.0 kW
HOTPLATE
inner rear right
102
1.8 kW (130g/hr)
82
65
17