AUS
7
TECHNICAL DATA
Oven dimensions
(HxWxD)
34x39x44 cm
Volume
58 l
Useful
measurements
relating to the
oven
compartment
width 42 cm
depth 44 cm
height 23 cm
Power supply
voltage and
frequency
see data plate
Burners
may be adapted for use with any
type of gas shown on the data
plate, which is located inside the
flap or, after the oven compartment
has been opened, on the left-hand
wall inside the oven.
ENERGY LABEL
Directive 2002/40/EC on the label
of electric ovens. Standard EN
50304
Declared energy consumption for
Natural convection Class – heating
mode:
Static
EC Directives: 2006/95/EEC dated
12/12/06 (Low Voltage) and
subsequent amendments -
89/336/EEC dated 03/05/89
(Electromagnetic Compatibility) and
subsequent amendments -
90/369/EEC dated 29/06/90 (Gas)
and subsequent amendments -
93/68/EEC dated 22/07/93 and
subsequent amendments -
2002/96/EC.
S S
R
A
Technical Specification
Gas Consumption
Natural Gas (1.0 kPa)
ULPG (2.75 kPa)
Injector
Diameter
Gas Input
Injector
Diameter
Gas Input
Auxiliary Burner
0.85 mm
3.7 MJ/hr
0.50 mm
3.1 MJ/hr
Semi Rapid Burners (x2)
1.10 mm
6.0 MJ/hr
0.64 mm
5.5 MJ/hr
Rapid Burner
1.29 mm
8.2 MJ/hr
0.80 mm
8.5 MJ/hr
Total
23.9
MJ/hr
22.6
MJ/hr
Connections
Gas Inlet fitting
1/2” BSP (male) thread
Location of gas inlets
at rear of cooker
222 mm from top of cooker
20 mm from left edge of cooker
Alternative inlet 20mm from right edge of cooker.
K3G11/AUS
K3G11S/AUS