After installing the power cable, screw the metal cover
with three screws.
9
or:
• the mains cable is wired directly into a 13 amp cable
outlet, controlled by a switch, (in compliance with
BS 5733) which is accessible without moving the
appliance.
! For appliances with a rating greater than 13 amp (eg:
electric hob, double ovens and freestanding electric
cookers etc.) the mains cable must be wired into a
cooker output point with a rating of 45 amp. In this
case the cable is not supplied.
Disposing of the plug:
Ensure that before disposing of the plug itself, you
make the pins unusable so that it cannot be
accidentally inserted into a socket. Instructions for
connecting cable to an alternative plug:
!!!!! The wires in the mains lead are coloured in
accordance with the following code:
Green & Yellow
- Earth
Blue
- Neutral
Brown
- Live
If the colours of the wires in the mains lead do not
correspond with the coloured markings identifying
the terminals in your plug, proceed as follows:
Connect Green & Yellow wire to terminal marked “E
EE
EE”
or or coloured Green or Green & Yellow.
Connect Brown wire to terminal marked “LLLLL” or
coloured Red.
Connect Blue wire to terminal marked “N
N
N
N
N” or
coloured Black.
If a 13 amp plug (BS 1363) is used it must be fitted
with a 13 amp fuse. A 15 amp plug must be
protected by a 15 amp fuse, either in the plug or
adaptor or at the distribution board. If you are in any
doubt about the electrical supply to your machine,
consult a qualified electrician before use.
How to connect an alternative plug:
The wires in this mains lead are coloured in
accordance with the following code:
BLUE
BLUE
BLUE
BLUE
BLUE
“NEUTRAL
NEUTRAL
NEUTRAL
NEUTRAL
NEUTRAL” (“N
N
N
N
N”)
B R O W N
B R O W N
B R O W N
B R O W N
B R O W N
“LIVE
LIVE
LIVE
LIVE
LIVE” (“LLLLL”)
GREEN AND YELLOW
GREEN AND YELLOW
GREEN AND YELLOW
GREEN AND YELLOW
GREEN AND YELLOW
“EARTH
EARTH
EARTH
EARTH
EARTH” (“E
EE
EE”)
GREEN &
YELLOW
BROWN
BLUE
13 amp fuse
CROSS-BAR
CORD GRIP
WARNING : This operation must be perfomed
by a qualified technician
*
At 15°C and 1013 mbar- dry gas
**
Propane
P.C.S. = 50,37 MJ/Kg
***
Butane
P.C.S. = 49,47 MJ/Kg
Natural
P.C.S. = 37,78 MJ/m
3
Table 1
Liquid Gas
Natural Gas
Burner
Diameter
(mm)
Thermal Power
kW (p.c.s.*)
By-Pass
1/100
Nozzle
1/100
Flow*
g/h
Nozzle
1/100
Flow*
l/h
Nominal
Reduced
(mm)
(mm)
***
**
(mm)
Fast
(Large)(R)
100
3.00
0.7
41
87
218
214
128
286
Semi Fast
(Medium)(S)
75
1.90
0.4
30
69
138
136
104
181
Auxiliary
(Small)(A)
51
1.00
0.4
30
50
73
71
78
95
Oven
-
2.80
1.0
46
80
204
200
119
267
Grill
-
2.30
-
-
75
167
164
114
219
Supply
Pressures
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
28-30
20
35
37
25
45
20
17
25
Table of burner and nozzle specifications
S S
R
A
TECHNICAL DATA
Power supply voltage
and frequency
see data plate
Burners
may be adapted for use with any
type of gas shown on the data
plate, which is located inside the
flap or, after the oven
compartment has been opened,
on the left-hand wall inside the
oven.