Indesit DOCTOR 2 Скачать руководство пользователя страница 13

 

 

 

 

 

 

 

 

MAIN SCREEN 

 
 
 

APPLIANCE DETAILS 

This area displays appliance details, option buttons, knobs and features. If the information displays correctly it indicates the 
Eeprom and power board are ok. If it is incorrect then the Eeprom or power board will need to be replaced before tests can 
be carried out. 
 

TEST COMPONENTS 

This area shows the various components the Wash Doctor software checks during the test. 

 
 

CONNECTION 

This area shows Connection port, Connection button, Statistics and Customer Info buttons. The Statistics of the test and the 
Customers information can be saved using these buttons.  
 

TEST BUTTONS 

 

These buttons select either an Automatic test or Single item test. There is also a Stop Test button and an ‘item OK’ button 
if required. The ‘Ko’ button is not applicable. In almost all cases, the Single and Automatic buttons are the only ones required 
for testing.  

 

 

 

13

Содержание DOCTOR 2

Страница 1: ...on Indesit Company UK Ltd 2006 Reg Office Peterborough PE2 9JB Registered in London 106725 Service WASHING MACHINE DOCTOR 2 A Guide for use with EMIT Model Types Covered EVO 2 Laundry 5407182 Issue 3...

Страница 2: ...ication carried out where necessary 7 It can be dangerous to attempt DIY repairs maintenance on complex equipment and the Company recommends that any problem with the appliance is referred to its own...

Страница 3: ...s 2 Date Code Serial Number Industrial Code 4 Introduction 5 Requirements Equipment 6 7 Connection to EMIT the Appliance 8 Starting the Software 9 Main Screen 10 13 Using the Software 14 29 Example Te...

Страница 4: ...on changes Second five digits COMMERCIAL CODE Vital for correct model information and system identification First two digits Factory of origin 1986 1994 2002 1987 1995 2003 1988 1996 2004 1989 1997 20...

Страница 5: ...h Doctor Evo 2 will work with laundry appliances manufactured with EVO 2 software It is important to read this guide fully and view the illustrations carefully before attempting to use the Wash Doctor...

Страница 6: ...re Emit Unit Hardware Key Part Number C00115587 Low End Adapter C00116135 USB to Serial lead Part Number 5600261 Hardware Key Pin Kit C00114723 Hardware Key Part Number C00115587 USB to Serial Cable P...

Страница 7: ...se products require an adaptor to connect the Emit to the appliance The adaptor is shown below Part Number C00116135 Information on the use of this adapter can be found in leaflet 8200787 Note This pr...

Страница 8: ...witch on the appliance Connect the Hardware Key to the appliance A Green Led illuminates on the key During communication with the software Orange and Red Led s on the Hardware Key will flash intermitt...

Страница 9: ...When you have the software loaded onto your Emit using the dropdown task bar select Washing Machine Doctor icon This will launch the multi button box shown Next select the WM Doctor Evo 2 button to la...

Страница 10: ...WASH DOCTOR EVO 2 MAIN SCREEN This screen will launch when the programme opens after selecting Wash Doctor Evo 2 button 10...

Страница 11: ...WASH DOCTOR EVO 2 MAIN SCREEN Press Connection and after a brief delay details of the current appliance will be displayed 11...

Страница 12: ...WASH DOCTOR EVO 2 MAIN SCREEN Main Screen APPLIANCE DETAILS TEST COMPONENTS TEST BUTTONS CONNECTION 12...

Страница 13: ...various components the Wash Doctor software checks during the test CONNECTION This area shows Connection port Connection button Statistics and Customer Info buttons The Statistics of the test and the...

Страница 14: ...a connection and establish the Eeprom and power board are correct in Hardware Configuration section there are two ways to test components Single as shown above or Automatic shown on page 19 In this c...

Страница 15: ...USING THE SOFTWARE SINGLE TEST Press the Single button and the software will check the component selected 15...

Страница 16: ...USING THE SOFTWARE SINGLE TEST A successful test result will display as shown This confirms the item is ok The result can be printed if required but at present this function is disabled 16...

Страница 17: ...USING THE SOFTWARE SINGLE TEST An unsuccessful test result will display as shown 17...

Страница 18: ...USING THE SOFTWARE SINGLE TEST If test is unsuccessful a Help File is available by clicking in the white area where the failure is listed A separate box appears with suggestions of possible faults 18...

Страница 19: ...OFTWARE AUTOMATIC TEST To test all the components shown simply select Automatic and the programme will progress through components 1 to 21 as applicable to the appliance Leave all the boxes with ticks...

Страница 20: ...USING THE SOFTWARE AUTOMATIC TEST A successful test result will display as shown This confirms the item is ok The result can be printed if required but at present this function is disabled 20...

Страница 21: ...ill display as shown In this example the pressure switch is stuck full FAIL NO CRITER indicates component NOT TESTED As the valves and the pump rely on the pressure switch they will not test The help...

Страница 22: ...USING THE SOFTWARE BOTH TESTS During Automatic test or Single test you will need to rotate the selector Slowly rotate selector until all Leds light up Then press OK 22...

Страница 23: ...USING THE SOFTWARE BOTH TESTS During Automatic test or Single test for models with variable knobs you will need to rotate them to confirm as shown The pop up window has a time limit 23...

Страница 24: ...USING THE SOFTWARE BOTH TESTS During Automatic test or Single test for models with a display you will need to confirm as shown This has a time limit 24...

Страница 25: ...USING THE SOFTWARE BOTH TESTS During Automatic test or Single test for models with Leds you will need to confirm as shown This has a time limit 25...

Страница 26: ...TEMPERATURE DURING TEST During the Solenoid Valve tests a pop up window appears showing the temperature of the water during the test 26...

Страница 27: ...USING THE SOFTWARE BOTH TESTS If you select Stop the test will cease If you press OK the test will bypass the current component and show it as failed The Ko button is not used 27...

Страница 28: ...USING THE SOFTWARE BOTH TESTS Customer Info screen enter information and when you close Wash Doctor the file is saved 28...

Страница 29: ...USING THE SOFTWARE BOTH TESTS This shows the Statistics of the test this is saved when closing Wash Doctor 29...

Страница 30: ...EXAMPLE TEST Console power board unplugged or detached wires Automatic Test was selected however the component would also fail a Single test 30...

Страница 31: ...or pressure switch stuck open Automatic Test was selected however the component would also fail a Single test This shows the valves or filling circuit failure and the pump not tested Note There is no...

Страница 32: ...EXAMPLE TEST Open circuit door Automatic Test was selected however the component would also fail a Single test 32...

Страница 33: ...EXAMPLE TEST Open circuit heater Automatic Test was selected however the component would also fail a Single test 33...

Страница 34: ...EXAMPLE TEST Open circuit drum thermistor Automatic Test was selected however the component would also fail a Single test 34...

Страница 35: ...EXAMPLE TEST Open circuit pump Automatic Test was selected however the component would also fail a Single test This shows the test was not carried out on valves and the pump failed 35...

Страница 36: ...EXTRA TEST An additional spin test can be carried out using the Extra Test button 36...

Страница 37: ...EXTRA TEST This window pops up showing the speed set on the appliance Press Start with the drum empty and the speed achieved is shown 37...

Страница 38: ...on of Wash Doctor is being used Impossible to read key Bad connection of key or cable between appliance and computer Check connections Wrong information displayed in Washing Machine Doctor Ensure appl...

Страница 39: ...NOTES 39...

Отзывы: