StorMonitor - Installation & commisionning - V2009.01 GB.doc – V2009.01
6
IV – Connection principles:
Diagram (see appendix 2 for more details):
Main technical data:
Power supply: 12Vdc typical, range from 11 to 13.6Vdc
Consumption at 12V (without alarm): 90 mA
Operating temperature range: -15 to + 60 °C
Antenna protection index: IP66
Sound alarm signal: via a buzzer incorporated into the processing unit, depending on the
position of the jumper SW12 located on the processing unit's circuit board.
Reset of the buzzer and "Memory" LED
2
d by a pressing the “Reset memory” button
5
on
the front panel.
Timeout of the "Storm in progress" alarm: 10 minutes, retriggerable by lightning occurring
during this timeout.
Alarm contact: NO, no voltage, rating 24Vdc/1A on resistive load.
For further details concerning use, please refer to appendices 1, 2 and 3.
END OF DOCUMENT
Antenna
Processing unit
J1
J2
Power supply unit
Buzzer, alarm, etc.
2
3
+12V
230 Vac
Yellow / green wire
0 V
Example of output interface