3.1 Battery voltage sensor

To protect the batteries from becoming completely 
discharged, a battery voltage sensor switches off the 
compressor automatically at the following levels:

System voltage V

Cut out V

Cut in V

12

9,6 (10,4)

10,9 (11,7)

24

21,3 (22,8)

22,7 (24,2)

If the bridge between C and P is cut off, values within the 
() are valid.

4 Installation instructions

Many boats have a space which is intended for a freezer. 
The Isotherm Cruise freezers have been designed to suit 
the general dimensions normally used for this purpose.
The compressor should normally stand upright in the boat, 
but will operate at an angle of heel up to 30° and for short 
periods even more. 
Avoid mounting the freezer close to a heat source, like gas 
ovens and heaters. Also avoid a position allowing direct 
sunshine on the freezer unit.
The mounting position should be dry and protected from 
splashing water.
For easier mounting of the freezer, use the mounting rails 
available as optional equipment, on the models not having 
three side mounting frame.

The INOX types have fl ush mounting frame as standard. 
The freezers shall be standing on the rubber feet and 
locked in position by means of the mounting frame or 
mounting rails. When no rails or frames are used the 
cabinet must be well fastened into the surrounding con-
structions.

4.1 Ventilation

It is very important that the compressor/condenser unit is 
well ventilated and that cold air can enter at the bottom, 
pass behind the freezer and warm air can leave at the top 
in the area where it is mounted. The natural fl ow of air from 
below and upwards behind the freezer can be increased 
by arranging ventilation openings at the rear.
Make sure there is a free area of 15 - 23 sq.in. below 
and behind the refrigerator to allow ventilation air to pass 
behind from below. See fi g.

4

4.2 Door front panel

The front panels on the doors can be replaced or addition-
al standard front panels in white, teak, mahogany or cherry 
can be mounted on top of the standard panel.
The INOX models have doors in stainless steel and do not 
have exchangeable door fronts.
Use a screwdriver or a knife as a lever and pull off the 
lower door profi le. Unscrew the three screws holding the 
door lock.
Mount the extra panel on top of the existing one, fasten the 
door lock again and push in the lower door profi le.
See fi g.

4.3 Reverse the door hinge

The doors on the freezers are as standard mounted with 
the hinges to the right hand side. 
The door can be hinged to the left by means of changing 
position of the upper and lower hinge fi ttings. 
The door lock must also be moved to the other side.
See fi g. above.
The upper hinge pin is threaded into the top part above the 
door, unscrew the top part to take off the door and move 
the pin to the other side. 
Or both the upper and lower hinge fi ttings are screwed into 
the cabinet and have to be taken off and mounted on the 
other side instead. The lower door support is also moved 
to the other side. 
CR INOX can also be re-hinged as described above. The 
door locking is placed in the middle and does not need to 
be re-positioned.
CR 90 Freezer INOX has left or right doors with side 
mounted door locks and cannot be changed.

Содержание CR 63F INOX

Страница 1: ...arine freezers Type CR 63F INOX CR 65F CR 65F INOX CR 90F CR 90F INOX DR 55F INOX Indel Marine USA Inc 3400 Gateway Drive Unit 107 Pompano Beach FL 33069 Tel 1 954 984 8448 1 800 422 9711 Fax 1 954 97...

Страница 2: ...emperature setting thermostat 2 2 User tips 2 3 Defrosting 3 Maintenance 3 1 Battery voltage sensor 4 Installation instructions 4 1 Ventilation 4 2 Door front 4 3 Reverse door swing 4 4 Electrical con...

Страница 3: ...X has the door made as a drawer instead lower drawer box and door is built together It has also an upper separate drawer For your own and others safety read this first Danger When connected to mains p...

Страница 4: ...rature with storage of non sealed food and the time the door is kept open Defrosting shall be made when the frost layer is more than 1 8 thick Set the thermostat in OFF position or switch off a main s...

Страница 5: ...leave at the top in the area where it is mounted The natural flow of air from below and upwards behind the freezer can be increased by arranging ventilation openings at the rear Make sure there is a f...

Страница 6: ...ize selected Do not connect the freezer direct to a battery charger The battery charger must be connected to the battery 4 5 Wire dimensions Wire gauge Max cable length in ft 12V Max cable length in f...

Страница 7: ...olt 2 Battery 3 Fan 4 Fuse 15A 12V 7 5A 24V 5 Additional electronic 6 Thermostat with temperature sensor DR 55 F INOX 1 Electronic unit 12 24 volt 2 Battery 3 Fan condenser 4 Inner fan 5 Thermostat 6...

Страница 8: ...iagram If compressor starts this indicates a faulty thermostat If the compressor does not start this indicates a faulty electronic unit or compressor Contact an authorized service agent A possible lea...

Страница 9: ...0 Freezer INOX B H DI CR 63 F INOX 19 1 2 24 5 8 21 3 4 CR 65 F INOX 21 7 16 24 5 8 20 3 4 CR 90 F INOX 21 7 16 29 5 16 21 3 8 B x H day opening min dimensions DR 55 Freezer INOX B H D1 DR 55 F INOX 1...

Отзывы: