User Manual
51
6 Troubleshooting
All work on electrical parts or electrical connections and the refrigerant circuit must
be carried out by qualified and authorised personnel.
Warning: Disconnect electrical power before performing any operations on electrical
parts or on electrical connections.
Defect
Possible cause
Intervention
The refrigerator does not
cool, the compressor will
not start.
No electrical power. Battery
in poor conditions. Faulty
thermostat. Defective
electronic control unit.
Check to make sure that the electronic
control unit is receiving sufficient power
and voltage; check the fuse. Verify that the
internal lighting is working and that the
compressor is receiving power. Check the
cables, lugs and connectors. Verify that
the battery is charging properly. Check the
thermostat: Bridge T - C with a separate
cable. If the compressor will not start,
its electronics are probably defective.
Replace. If the compressor starts up with
the bridge, the thermostat is defective.
Replace the thermostat.
The compressor only
performs brief attempts at
starting up.
There is insufficient voltage or
else a drop in voltage during
the attempt to start. The
protection device is activated.
The Batteries are drained.
Check the cables and connections; remove
any traces of oxidation or corrosion.
Charge the batteries, start the motor or
connect the battery charger.
The compressor functions
but doesn’t cool.
Loss of refrigerant through
the evaporator or the tubing.
Tubing clogged.
Carry out a leak check and repair any
leaks, drain and refill the proper amount of
R134a refrigerant. (This operation must be
carried out by a qualified technician.)
The compressor runs for
a long time but doesn’t
cool properly (reduced
efficiency).
Insufficient ventilation,
the condensation unit is
overheating. The fan is not
working properly. There is too
much frost on the evaporator.
The door does not close
properly and lets in warm,
moist air. The condenser is
blocked by dust.
Increase the ventilation. Replace the fan.
Defrost the unit. Correct the position of
the door and check the gasket. Clean the
condensing unit.
Содержание FR115EL
Страница 2: ......
Страница 3: ...3 Isotherm Free Line Elegance Serie Fig 1 Fig 2...
Страница 4: ...4 Isotherm Free Line Elegance Serie Fig 3 Fig 4...
Страница 5: ...5 Isotherm Free Line Elegance Serie Fig 5 Fig 6...
Страница 6: ...6 Isotherm Free Line Elegance Serie Fig 7 Fig 8...
Страница 32: ......
Страница 58: ......
Страница 84: ......
Страница 110: ......
Страница 136: ......
Страница 162: ......
Страница 188: ......
Страница 214: ......
Страница 216: ...216 1...
Страница 217: ...217 INDEL Webasto Marine S r l 1 2 2002 96 RAEE...
Страница 218: ...218 R134a R134a R134a 1 3 Indel Webasto Marine S r l...
Страница 219: ...219...
Страница 220: ...220 115 230 8...
Страница 221: ...221 2 SN 10 C 32 C N 16 C 32 C ST 16 C 38 C T 16 C 43 C 2 1 1 1 1 1 ECO 2 3 ECO 12Vdc 9 6 17 0Vdc 24Vdc 21 3 31 5Vdc 5...
Страница 222: ...222 1 C 34 9 C 48 F 1 2 3 4 3...
Страница 223: ...223 ECO ECO 13 5Vdc 25 5Vdc 60 1 C 12 5Vdc 24 5Vdc ECO 3 ECO ECO ECO 12 5Vdc 24 5 Vdc 60 ECO ECO...
Страница 224: ...224 2 2 6 Indel Webasto Marine S r l 30...
Страница 225: ...225 2 3 3 4 3 Isotherm Cruise Cruise Elegance 0 C...
Страница 226: ...226 Free Line Elegance TO VENT 4 3 1 12 9 6 10 4 10 9 11 7 24 21 3 22 8 22 7 24 2...
Страница 227: ...227 4 Indel Webasto Marine S r l...
Страница 228: ...228 EN 603335 1 5 Heavy Current Regulations 115 230...
Страница 229: ...229 4 1 Isotherm 30 Elegance Easy Fix 8 Easy Fix 10 6 2 EN 60335 2 24...
Страница 230: ...230 4 2 1 2 3 4 3 Free Line Elegance 4 7 Indel Webasto Marine 4 4 Isotherm Free Line Elegance 5...
Страница 231: ...231 4 5 12 24 I 0 03A 12 24 Free Line 115 Elegance 15A 7 5A...
Страница 233: ...233 6 T C R134a 4 4...
Страница 234: ...234 C P C T...
Страница 235: ...235 Indel Webasto Marine Isotherm...
Страница 236: ...236 7 5 1 5 5 1 2 1A 3 5 4 1850 5 6 7...
Страница 238: ...238 9 Indel Webasto Marine 1999 44 Isotherm 2 IWM b S N...
Страница 240: ...240 Isotherm Free Line Elegance Free Line Elegance DC 12 24 Volt...
Страница 241: ...241 Isotherm Free Line Elegance Free Line Elegance DC 12 24 Volt AC DC 100 240 Volt...
Страница 242: ......
Страница 243: ......