REFRIGERAZIONE MOBILE - FRIGOBAR
ISO 9002 certified
TB 15-18
TB15-18_00_03-2012
17
ENGLISH
DEgREES fAhRENhEIT/CENTIgRADE
To set the temperature unit of measurement to degrees
Fahrenheit or Centigrade, activate symbols
F
or
C
OvER - COOLINg
The Over - Cooling function, described above, is set
by activating symbols
o C
.
fAULTS
Any operation faults will be displayed after 90 seconds and will be presented on the display with the
following codes:
1
The thermostat has short-circuited or is not correctly connected to the control unit:
R6
2
The compressor is blocked:
R3
3
The ventilator is sending the control unit a value which exceeds 0.6A:
R2
4
The cooling system holds too much gas and the compressor is not able to operate
at the minimum number of revolutions/rpm:
R4
5
The ambient temperature is too high:
R5
6
Insufficient voltage (Voltage below the cut-out value):
Lo
7
No communication between the display and control unit, a
scrolling horizontal
line
appears on the DISPLAY for a few seconds, the refrigerator turns itself off.
-
Содержание TB15