E
N
GL
ISH
39
The following are the menus which can be modified:
P0
- Timer (MIN and AUTO modes)
In MIN and AUTO mode, the system’s default setting is
6 hours
of
continuous operation. The default value can be changed in this menu.
The choice range is between
1
and
99
hours.
P1
- Timer (MAX mode)
In MAX mode, the system’s default setting is
4 hours
of continuous
operation. The default value can be changed in this menu. The choice
range is between
1
and
99
hours.
A2
– Centigrade and Fahrenheit
degrees
The system’s default setting is
Centigrade degrees
. This menu allows
you to change the parameter to
Fahrenheit degrees
.
A3
- Offset
This refers to the temperature difference detected by the probe and the
temperature shown on the display. This menu allows you to change this
value from
-9°C
to
+9°C
with
1°C
increments.
A4
- Max condenser fan speed
The cooling fan’s speed is variable and depends on the operation of the
compressor. Its default setting is
100%
of its operational power. Its
maximum speed can be reduced (for example if it is too loud) according
to the following table. Bold values are its default settings.
WARNING: if the selected speed value is too low, the compressor
may overheat and the device may shut itself down (see error table –
code
E3
–
E4
–
E5
).
Level
Percentage
10
100%
9
90%
8
80%
7
70%
6
60%
5
50%
4
40%
A5
– Battery saver value
Its default setting is
21.5 Vdc
(Cut-out) and
24 Vdc
(Cut-in). This menu
allows to change the values according to the following table. Default
values are in bold.
Vm
24Vdc
Vm
24Vdc
Cut-out
Cut-in
Cut-out
Cut-in
0
20
24.5
10
20
24
1
20.3
11
20.3
2
20.6
12
20.6
3
20.9
13
20.9
4
21.2
14
21.2
5
21.5
15
21.5
6
21.8
16
21.8
7
22.1
17
22.1
8
22.4
18
22.4
9
22.7
19
22.7