Intended Use and Medical Indication

Yscope is mainly used for healthy and obese patients in hospitals, medical practices and inpatient care facilities 
in accordance with national regulations. It can be used to assist in the assessment of the abdominal obesity. Body 

Fat distribution analysis is an important factor in preventive medicine since it provides the basis of appropriate 
physical activity and dietary habits for improving personal daily routine. It can be also usefully applied to follow-
up studies of patients treated for various diseases.

• Obesity: Percent body fat is considered to be more appropriate but the distribution of body fat may be more 
  important to health than the classification of obesity or the total amount of body fat. Visceral fat obesity is more 
  frequently accompanied by circulatory disorders, and the aging is therefore associated with a shift of fat to a more 

  central fat deposition, especially to the visceral. 

• 

Diabetes & Endocrinology: Diabetes is often associated with excess fat, however having insufficient muscle mass 

 

  is just as detrimental and increases diabetes risk. Visceral fat also plays a key role in the development of 
  metabolic and cardiovascular disease.

* The Yscope is not a diagnostic device. To make an accurate diagnosis, a physician must go through a thorough 
   examinations and take their results into account in addition to the results of the Yscope.
* The Yscope is not used in home healthcare environment. 

Содержание Yscope

Страница 1: ...e and Setup Thank you for purchasing the Yscope This user s manual describes all the features of the Yscope Please read before use and keep it in a safe place By following properly these instructions...

Страница 2: ...more appropriate but the distribution of body fat may be more important to health than the classification of obesity or the total amount of body fat Visceral fat obesity is more frequently accompanie...

Страница 3: ...y the appearance specifications and etc of the Yscope to improve the quality of the product without prior notice for reasons of performance improvement Representative Sponsor Information InBody Europe...

Страница 4: ...4...

Страница 5: ...rcumference Measurement A Precautions for Measurement B Measuring Posture and Measuring Method IV Transportation and Storage A Cautions during Transportation B Repacking Instructions C Transportation...

Страница 6: ...the following components Make sure all of the components are present Please check each component of the system for damage prior to installation If you have any issues contact our Product Support team...

Страница 7: ...tive film Please avoid using the Yscope in wet conditions as extreme temperatures humidity and air pressure can affect its performance Generally internal batteries have an appropriate storage temperat...

Страница 8: ...wered on InBody InBody USB port Ring Rubber groove InBody Caution Installthechargingstationonaflatandvibration freefloor Ifinstalledonanunevenfloor thereisariskoftheYscopedroppingifthechargingstationf...

Страница 9: ...have enough power Do not disassemble the equipment arbitrarily This may cause electric shock or injury product malfunction and inaccurate results as well as void the manufacturer s warranty If the Ys...

Страница 10: ...rial number can be found at the rear of the product If the product cannot be found refresh to search again 5 Disconnect the product from the charging station and press the button and the button at the...

Страница 11: ...th the button 3 You can set the value of each item with the button The line at the bottom displays the currently selected value If you set Beep to OFF audio notifications will be disabled 4 When finis...

Страница 12: ...ng Do not use it for purposes other than the measurements presented in this user manual Foreign substances may affect the measurement electrode Wipe it with a clean soft cloth after each use The batte...

Страница 13: ...nts When measuring refer to the user manual and measure in order Please measure in comfortable clothes Ifyoumeasurewhilewearingawaistbeltmadeofmetal themeasurementvaluemaybeskewed Iftheabdominalskinis...

Страница 14: ...ect apply diagonal force toward product with the measuring area For accurate measurement the subject should stand with their arms folded in front of their chest providing clear access to the abdomen P...

Страница 15: ...Frequently asked questions and answers or call Product Support 4 When the measurement is completed Complete is displayed on the screen along with a beep sound When the measurement is completed by pre...

Страница 16: ...ject Stand on the right side of the subject and let the wheel come next to the navel III Caution Proper posture for waist circumference measurement Waist circumference measurement Adjust the starting...

Страница 17: ...checking the waist circumference press the button on the product and the measurement data is transmitted to the linked InBody device Since the Yscope estimates the total waist circumference by measur...

Страница 18: ...onnected cables and place the manipulator on the corresponding insert Wrap the equipment in packaging and place it in the packaging box then seal the package securely with tape C Transportation and St...

Страница 19: ...close to the stomach and measure theelectrodesaccording to the pressure gauge pressure and try measuring again Those who are very thin may have this problem because they do not have sufficient contact...

Страница 20: ...d without maintaining the proper pressure the impedance value may be inaccurate so please observe the measurement method Thewaistcircumferencevalueis measureddifferentlythanthetape measure Since the Y...

Страница 21: ...nt waist measurement check Retry button Used when setting preferences measuring abdominal impedance and measuring errors during waist circumference measurement Done button Used during the first measur...

Страница 22: ...Yscope main unit for charging Mounting magnet Component that orients the Yscope in a fixed position Cable groove Organizes the cable to the bottom of the station B Safety Information Warning caution...

Страница 23: ...tion 260 X 260 X 790 mm 10 2 10 2 31 1 in Equipment Weight Main unit 0 3 kg 0 7 lb Charging station 2 5 kg 5 5 lb Testing Time Impedance measurement within 5 seconds Operation Environment 10 40 50 104...

Страница 24: ......

Страница 25: ......

Страница 26: ...inbody com 2021 InBody Co Ltd All rights reserved IM ENG L1 C 211105 1639...