24
SmartNode SN2400 Hardware Description
Port
Description
ETH 0/0
(10 / 100BaseT)
10/100BaseT Ethernet RJ-45 socket to connect the SmartNode to an Ethernet
device, such as a wide area transmission modem, Ethernet hub or switch.
ETH 0/0 is a host port; it can be connected with a straight wire (1:1) to a hub,
or a crossover cable to a host port.
The ’Link’ LED to the left of the connector is lit when the port is connected
correctly to an active Ethernet device. The ’100Mb/s’ LED, also to the left of
the connector, is lit when the port is connected correctly to an active
100BaseT Ethernet device.
ETH 0/1
(10 / 100BaseT)
same as ETH 0/0
Console
(RS-232)
RS-232 RJ-45 connector to connect the SmartNode with a serial terminal such
as a PC or workstation with a RS-232 interface, with the following settings:
9600 Baud, no parity, 8 Bit, 1 Stop bit, 1 Start bit
The console port is only used for service and maintenance purpose.
Caution:
Do NOT plug in an ISDN connector. The voltage on the S-Bus may
permanently damage the console interface.
Table 4-1: SmartNode SN2400 Port Description
In addition two other elements the Reset button and power lines socket are available on the rear
panel of a SN2400 as described in Table 3-2 below.
Element
Description
Reset button
The button has three different functions:
•
Manual Restart:
During normal operation pressing and releasing the
reset button will cause a system reboot. The application will be restarted
without any change to the existing SW configuration.
•
Restoration:
Pressing and holding the reset button for 5 seconds will
restore the factory configuration and automatically reboot the system.
Caution:
In this case the existing IP SW configuration is lost.
•
Boot loader:
Powering the SmartNode while pressing the reset button
for 5 seconds will cause the factory-fitted boot loader to start in place of
the application. The boot loader uses a minimal set of parameters. In
case the application does not start correctly, the boot loader can be used
as a fallback to download a new software version.
100 - 240VAC
50/60 Hz
Electricity supply socket for AC mains power cable.
Warning:
The mains supply
must
be secured with an external fuse or circuit-
breaker, with a maximum tripping current of 16A.
Ext. Pwr
48 VDC
+/- 20%
Electricity supply socket for DC mains power cable.
The external power supply connected to this socket must comply with the
EN/IEC 60950 standard. It must be a current source with power limitation
according to EN/IEC 60950. Its primary circuit must be isolated from the
secondary twice or in an enhanced manner.
Table 4-2: SmartNode SN2400 Reset Button and Power Line Sockets on Rear Panel
Hardware Installation Guide, Revision 3.11