background image

 
 

 

8

 

 

VP-422 Specifications

 

Rev3.2 

 

9. Connection Method / Instruction Manual 

Operation for Direct Output Vibration Pick-up is as below figure 1. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fig.1 Example of Connection method 

 

Caution on cable connection and instruction 

(1) Confirm “+” and “–” polarity first. If the polarity is opposite, sensor cannot operate. 
(2) Do not supply power voltage more than the specification. It will cause breakdown on sensor. 
(3) Shield wire (Silver) connect on minus side of power supply. 
(4) In case of using any receiver such as logger with 1-

5V, connect 250Ω resistance with it in 

parallel. 

(5) When relaying cables, be sure to use cable junction box. Also, take measures to prevent 

disturbance noise from entering. If noise countermeasures are not implemented, correct 
measurement results may not be obtained. 

 

10. Warranty 

If there is any breakdown caused by producing error, material fault, or obviously our fault, we 

repair or exchange with no charge. This condition is valid only in warranty term and the term is for 1 
year after delivered. However, even if it is under warranty, it will occur some charge on exchanging. 

(A) Any damage and breakdown caused by natural disaster such as fire, earthquake, flood, 

lightning damage. 

(B) Any transporting, moving, or dropping which does not related us after finishing our 

delivery. 

(C) Any error operation, unusual power supply input, and the fault caused by 

disassembling/repairing/modifying by customer. 

Power Supply 

15 to 30VDC 

 

4-20mA Logger 

Black 

White 

Silver 

PLC/DCS etc. 

 

 

 

VP-422 

<Case of 4-20mA Logger> 

Power Supply 

15 to 30VDC 

 

1-5V Logger 

Black 

White 

Silver 

PLC/DCS etc. 

 

 

 

250Ω

 

<Case of 1-5V Logger> 

Содержание VP-422

Страница 1: ...ations Rev3 2 Specifications and Instruction Manuals Direct Output Vibration Pick up 4 20mA Acceleration Type Model VP 422 Manufacture IMV CORPORATION Specification No TVE 5 5678 Total Page 8 Revision Date 20th Dec 2018 ...

Страница 2: ...line 3 2 Feature 3 3 Typical Applications 3 4 Specifications 4 5 Outline Dimensional Drawing 5 6 Vibration Pickup Mounting Studs 6 7 Frequency Response 6 8 Outline View of Connector Cable 7 9 Connection Method Instruction Manual 8 10 Warranty 8 ...

Страница 3: ...BMS or 4 20mA input module 2 Feature 1 Output is 4 20mA DC which is proportional to the vibration level 2 This product has the capability of interfacing direct into PLC BMS or 4 20mA input module 3 Typical Applications 1 Vibration Sensors of Vibration Monitoring systems for manufacturing plants or machine tools 2 Built in vibration sensors for fans motors Compressors etc ...

Страница 4: ... φ27 5 56mm Excluding Protrusions Water Resistant Type φ27 5 69mm Excluding Protrusions Detail Reference 5 Outline Dimensional Drawing Weight Drip Proof Direct Connect Type 135g Excluding Cables Water Proof Connector Type 150g Excluding Cables Water Resistant Type 140g Excluding Cables Case Material Stainless Steel SUS303 Output Cable Drip Proof Direct Connect Type 2 Core Shielded Cable 5m Standar...

Страница 5: ...tor Type Water Resistant Type Sensor Body Cable White 15 to 30VDC Black 0V Silver Sensor Body Cable White 15 to 30VDC Black 0V Silver φ 27 5 45 HEX 28 W5 8 depth 6mm φ 27 5 HEX 28 56 66 5 W5 8 depth 6mm Sensor Body Connector Shape Pin1 no connection Pin2 15 to 30VDC White Pin3 no connection Pin4 0V Black φ 27 5 HEX 28 69 44 φ 5 2 W5 8 depth 6mm ...

Страница 6: ... Mounting Studs Quick Fit Glue face Quick Fit M8 Male Quick Fit M6 Male Quick Fit φ25 4mm Pole Piece Pot Magnet Unit mm 7 Frequency Response Frequency Hz Frequency Response dB 24 W5 8 5 5 3 5 6 24 8 5 3 5 W5 8 M8 6 24 8 5 3 5 M6 W5 8 25 5 3 19 3 5 W5 8 ...

Страница 7: ...pecifications Rev3 2 8 Outline View of Connector Cable Brown White Silver Shield Blue No use Black Brown White Silver Shield Blue No use Black MS AC010 Straight Connector MS AC011 Angle Connector φ15 φ15 28 46 46 ...

Страница 8: ...easures are not implemented correct measurement results may not be obtained 10 Warranty If there is any breakdown caused by producing error material fault or obviously our fault we repair or exchange with no charge This condition is valid only in warranty term and the term is for 1 year after delivered However even if it is under warranty it will occur some charge on exchanging A Any damage and br...

Отзывы: