background image

 
 

  4 

 

VP-420/421 Specifications Rev5.0 

 

For Safe Use 

   

Warning 

(1) Do not use this product as a life-threatening alarm device. 
(2) When installing this product or peripheral devices in a high place, be sure to use a 

workbench such as a stepladder. 

(3) Do not use in abnormal conditions such as smoke, strange odor, or noise. Also, do not 

disassemble or modify this product regardless of whether it is normal or abnormal. It 
may cause electric shock, fire, or malfunction. 

(4) When installing near a moving part of the machine, make sure that the machine is stopped 

before installing it. Do not perform any installation work while the machine is in operation. 

 

   

Caution

 

(1) Be sure to wear a helmet when working at heights. 
(2) When installing this product or peripheral devices in a high place, fix them firmly. If 

this product or peripheral devices fall, an accident may occur. 

(3) When the product is energized, do not touch the terminal block etc. carelessly.

 

 

Note

 

(1) When wiring pickup, check the method that matches the specifications of the device 

to be connected. Improper connection may cause the product or connected devices to 
breakdown or be damaged. 

(2) Use this product in the environment described in this manual. If you use it in an 

environment not described in this manual, unexpected problems may occur. In 
addition, if the main unit is damaged or peripheral devices are damaged due to the 
above reasons, the warranty will be void. 

(3) Do not attach this product to the interference point or operating point of the object to 

be measured. The object to be measured may damage. 

 

Memo 

(1) This product is a precision device. Please handle with care. 
(2) When performing automatic measurement operation using this product, it may not be 

possible to record measurement data as expected if the settings are not correct. 
Please check in the actual environment whether the measurement data can be 
obtained as expected, and after confirming that there are no problems, start 
operation at full scale. 

 

 

Содержание 4P-420

Страница 1: ...nstruction Manuals Direct Output Vibration Pickup Model VP 420 4 20mA Velocity Type VP 421 4 20mA Velocity AC Acceleration Type Manufacturer IMV CORPORATION Specification No VP 420 TVE 5 5676E VP 421...

Страница 2: ...sions 7 4 Outer Dimensions of Mounting Adapter Quick Fit 8 5 Frequency Response 8 6 Outline View of Connector Cable 9 7 Instructions 10 7 1 Installation of Pickup 10 7 2 Laying of Pickup Cable 10 7 3...

Страница 3: ...is instruction manuals and attached documents before use and fully understand the contents for use After reading this manual be sure to place it in a location so that you can always refer to it Expres...

Страница 4: ...zed do not touch the terminal block etc carelessly Note 1 When wiring pickup check the method that matches the specifications of the device to be connected Improper connection may cause the product or...

Страница 5: ...rements based on ISO10816 which defines the vibration severity is possible by this product 2 Output is 4 20mA DC which is proportional to the vibration level 3 This product has the capability of inter...

Страница 6: ...ax at 24VDC Dimensions Detail Reference 3 Outer Dimensions Drip proof Direct connect Type 27 5 45mm Excluding Protrusions Water proof Connector Type 27 5 56mm Excluding Protrusions Water Resistant Typ...

Страница 7: ...27 5 HEX 28 56 66 5 W5 8 Depth 6 Sensor Body VP 420 Pin Assign Pin1 NC Pin2 15 to 30VDC White Pin3 NC Pin4 0V Black 27 5 HEX 28 69 44 5 2 W5 8 Depth 6 Sensor Body VP 420 Cable White 15 to 30VDC Black...

Страница 8: ...Mounting Adapter Quick Fit MS AS001 for Glue Face MS AS002 M8 Male MS AS003 M6 Male MS AM005 Magnet 25 4mm Pole Piece Unit is mm 5 Frequency Response 24 W5 8 5 5 3 5 6 24 8 5 3 5 W5 8 M8 6 24 8 5 3 5...

Страница 9: ...heath Material PUR Cable Outer Diameter 5 9 Standard Outline View See below Figure Brown White Silver Shield Blue No use Black MS AC010 Straight Connector MS AC011 Angle Connector 15 15 28 46 46 Brown...

Страница 10: ...ickup mounting surface cleanly finished Completely remove dirt dust paint etc Also make sure that the tapped holes are upright with no foreign matter on the threads 7 2 Laying of Pickup Cable 1 Pickup...

Страница 11: ...eceiver such as logger with 1 5V connect 250 resistance with it in parallel Fig 7 2 is just an example of wiring For details on connecting pickup to the receiver Logger PLC DCS etc refer to the instru...

Страница 12: ...with it in parallel Fig 7 3 is just an example of wiring For details on connecting pickup to the receiver Logger PLC DCS etc refer to the instruction manual of the receiver Also check the instruction...

Страница 13: ...pose of it as industrial waste 9 Warranty If this product has the fault caused by the responsibility of IMV as the defect under production and material during warranty period we will repair or replace...