PHYSICAL INSTALLATION

It is imperative that the lights are mounted in such a location that 

the fixtures are protected from the rear against water exposure.  

Also, it is important that the lights are mounted with airspace 

around the heat sink housing to allow for convective cooling 

of the lights.  We recommend a distance of ½” (13mm) of free 

space above the housing.

 

 

 

 

- 4 -


‚

½” (13mm)

Resonance suppression 

band (do not remove)

„

Spring Mount Installation Instructions

1.  A. For Sardinia/Cyprus fixed 

direction models:  Cut a 2 7/8” 

(73mm) diameter circle in the 

mounting surface.

  B. For Cyprus Eyeball:  Cut 

a 3 3/8” (85mm) circle in the 

mounting surface,  Note: the hole 

must not be any larger than this.

2.  Connect the light to an AC power 

source following the Wiring 

Instructions in the next section of 

this guide. 

3.  Once all electrical connections are 

made and secure, gently bend 

back the mounting springs of your 

PowerLED and insert the spring 

tips into the cutout circle in the 

mounting surface (see Figure 1).

- 5 -

 

 

 

 

Figure 1

Screw Mount Installation Instructions

1.  For Sardinia/Cyprus fixed direction 

fixtures:  Cut a 2 7/8” (73mm) diameter 

circle in the mounting surface.

2.  Connect the light to an AC power 

source following the Wiring 

Instructions in the next section of this 

guide. 

3.  Once all electrical connections 

are made and secure, insert your 

PowerLED into the cutout circle and 

fasten with #4 flat head screws (see 

Figure 2).

4.  Place the trim ring over the light 

making sure the tabs of the housing 

engage the openings of the trim ring.  

Twist the trim ring on to secure it.

Figure 2

Use #4 flat head 

screws only

- 6 -

- 7 -

WIRING INSTRUCTIONS

1.  Wiring connections shall be made within 

the necessary enclosures (junction boxes) as 

required by any applicable standards, codes 

or laws.  The available bracket and Molex

TM

 

connector may be used where appropriate.  

Otherwise, 18” of triplex cable is provided to 

allow proper wire routing to a suitable location.

2.  Connect the light to an AC power source by connecting the 

white wire to neutral, the black wire to live and the green/

yellow wire to ground.  

3.  If a dimmer is used, the black wire should be connected to the 

terminal or wire labeled “LOAD” on the dimmer.

4.  Please refer to wiring diagrams and dimmer compatibility 

chart on pages 8-11.  

Wire

Function

Black

Live

White

Neutral

Green/Yellow

Ground

IP40 & IP65 models

IP65 models only

Отзывы: