Imtra C2-107 Скачать руководство пользователя страница 3

 

3

 

Physical Installation 

 

1.

 

Determine the location where fixture will be mounted.  Be sure you 
have chosen the correct model for the application.  The HT models are 

specifically designed to be mounted upside down in a hanging 

position.  The non HT models should only be used for upright 
mounting.  If you do not have the correct model, please return it in 

exchange for the appropriate type. 

2.

 

Remove the mounting bracket from the floodlight by loosening and 
removing the tilt adjust nut and bolt. 

 

Thru-bolt installation (optional) 
3.

 

Identify mounting location 

and drill a ½” (12mm) 

mounting hole. 

4.

 

Remove the lock nut, split 

washer and nut from the 

12mm mounting bolt (sold 
separately) and pass the 

12mm mounting bolt through 

the mounting bracket and 
mounting hole.  Secure the 

bracket with the nut, split 

washer and lock nut. 

Surface mount installation 
3.

 

Identify mounting location 

and drill 4 pilot holes for #8 

self-tapping fasteners.  Use 
the mounting bracket as a 

template for these holes. 

4.

 

Secure the mounting bracket 
with four #8 self-tapping 

fasteners. 

 
 

 

5.

 

Attach the floodlight to the mounting bracket by passing the tilt adjust 

bolt through the bracket, spring washer, light housing, spring washer, 
bracket, split washer and nut. 

6.

 

Set the tilt height and tighten the Tilt Adjust Nut. 

Wiring Instructions

 

 
1.

 

Before making wiring connections, be sure the power is off! 

2.

 

Connect the white wire from your PowerLED Floodlight to DC (+). 

3.

 

Connect the black wire from your PowerLED Floodlight to DC (–).  

4.

 

Turn the power to the light on.

 

 

 

 
 
 

Wire 

Function 

Red (or White) 

Black 

 