![IMS PULSEMIG 270 Скачать руководство пользователя страница 23](http://html.mh-extra.com/html/ims/pulsemig-270/pulsemig-270_manual_2049891023.webp)
23
IMS PULSEMIG 270
EN
Pressing the trigger will initiate pre-gas. When the wire touches the workpiece a pulse boots the arc. The
machine initiates the Hot-start, upslope and then the welding process begins. When you release the trigger
the downslope will start until the Iblackout is reached. At this point a peak of current will cut the wire and
follows the post-gas. As in standard mode, you can carry on the welding during the post gas. Wait until the
end of the post gas to modify the parameters.
4 times pulse process
O
N
Is
ta
rt
Dstart
I h
ot
s
ta
rt
T hotstart
T upslope
G
as
P
re
-F
lo
w
T downslope
I Blackout
T burn-back
I b
ur
n-
ba
ck
O
N
O
FF
O
FF
Gas post-Flow
4T
4T
Soft-start
I
In 4T Pulse, the trigger will manage the time of the Hotstart and downslope.
SD card
SD
The SD card allows the operator to save the original settings. An
SD card should ALWAYS be used when undertaking a « total »
reset.
After resetting the parameters and to avoid the upload of these
ones each time you switch on your machine, push the SD card in
order to remove it. By this way, the card stays in the machine but
it can’t be read.
Password:
The password by default is: 0000.
In case of loss, the super user password allows you to unlock the
unit: MORWAS
To reactivate the standard password (0000), you need to reset
completely the machine. Read paragraph « reset ».
X / 60974-1 @ 40°C
(T cycle = 10 min)
I max
60% (T cycle = 10 min)
100% (T cycle = 10 min)
PULSEMIG 270
20% @ 270 A
190 A
170 A