CONNECTING THE UNIT 
General 
The connections to the unit are shown in Figure 2. 
 
Input Power Connections 
Power must be connected to the unit only at the terminal block labelled "POWER INPUT". 
This input is polarity-sensitive and must be connected as indicated on the PCB by the “+” 
and “-“ symbols. 
 
RS485 Communications Connections 
All communications cable should be screened. The cable screen should be connected to 
the PCB terminal labelled “RS485 ETH”, and this terminal should in turn be connected to a 
good EARTH ground. Connect each unit individually to ground to prevent possible ground 
loops. 
 
Remote Reader Power Connections 
The output power cable to the Remote Reader must be connected at the terminal blocks 
marked "REMOTE UNIT 5V OUT".  The Remote Readers are generally polarity-sensitive, 
and must be connected correctly as indicated using the "+" and "-" symbols. 
 
Remote Reader Communications Connections 
When connecting the ImproX DT Terminal to a Remote Reader of types MR, KR, MHR, 
KHR and CR, it must be remembered that the "Tx" terminal on the ImproX DT Terminal 
must be connected to the "Rx" terminal on the Remote Reader, and vice versa. It is 
recommended that the cable screen be connected to the "Remote Unit 5V Out -" terminal 
at the ImproX DT Terminal, and to the "POWER -" terminal at the Remote Reader as 
shown in Figure 2. 
 
For an Impro 4-Channel UHF Receiver connection, the "Remote Unit 5V Out” terminals 
must be connected to the 5V input of the UHF Receiver.  The selected channel output from 
the UHF Receiver must be connected to the “Comms RX” terminal and the selected 
channels “GND” terminal connected to the "Remote Unit 5V Out-“ at the DT.    
 
Cable length 
The recommended maximum length of the Remote Reader communications cable is 20 
metres. 
 
Jumper Settings 
If the unit is the last unit at the end of the RS485 communications bus (i.e. furthest from 
the associated controller), and the transmission lines are long or multiple “star” 
connections are used, there will be a danger of reflections occurring on the 
communications bus and disrupting communications. To prevent this, the jumper located 
adjacent to the RS485 Terminal Block on the last unit in the chain must be connected. 
 
NOTE :  

This jumper must only be connected at the unit at the end of the bus, 

not

 at 

every unit. 

 

Содержание XDT900-0-0-GB-XX

Страница 1: ...MODEL XDT900 0 0 GB XX ImproX DT Door Terminal INSTALLATION MANUAL Manual ref number XDT300 0 0 GB 01 Issue 2 July 2001 ...

Страница 2: ...r liability for any products or parts which have been subject to misuse accident negligence failure of electric power or modification by the Customer without Impro Technologies Pty Ltd written approval Final determination of warranty eligibility shall be made by Impro Technologies Pty Ltd If a warranty claim is considered invalid for any reason the Customer will be charged for services performed a...

Страница 3: ...ommunications Connections 8 Remote Reader Power Connections 8 Remote Reader Communications Connections 8 Jumper Settings 8 Relay Outputs 8 BUS ACTIVITY LED INDICATORS 9 ADDRESS ALLOCATION 9 TYPES OF ADDRESSES 9 Fixed Address 9 Address Allocation ImproNet Systems 9 Address Allocation OEM Systems 9 RECORDING OF INSTALLATION INFORMATION 10 Installation Information 10 Entering Installation Information...

Страница 4: ...ed for indoor mounting only SPECIFICATIONS PHYSICAL SPECIFICATIONS Dimensions Length Width Height 105 mm 4 14 116 mm 4 57 54 mm 2 13 Weight 115 g 4 05 oz Housing material Aluminium Colour Black ENVIRONMENTAL SPECIFICATIONS TEMPERATURE Operating 25o C to 70o C 13o F to 158o F Storage 40o C to 80o C 40o F to 176o F HUMIDITY RANGE 0 to 95 relative humidity at 40o C 104o F non condensing EMC EN55024 E...

Страница 5: ...y and over voltage protection RELAYS A single relay is provided DIGITAL INPUTS Type 2 x dry contact inputs Protection Range 80 V and 80 V single pulse 36 V and 30 V continuous RELAY OUTPUT SPDT N O N C and Common contacts RELAY CONTACT RATINGS 10 A at 28 V DC 5 A at 220 V AC ANTI TAMPER SWITCH Detects the opening of the unit enclosure RAM 2 Kbytes FLASH ROM 128 Kbytes EEPROM 2 Kbits TERMINAL BUS P...

Страница 6: ...otocol TEST MODES Power On Self test RAM ROM EEPROM OPERATOR INTERFACES STATUS INDICATORS Power on indicator Red LED externally visible Incoming RS485 Data Green LED flashing internally visible Outgoing RS485 Data Red LED flashing internally visible IMPROX PROTOCOL The unit communicates with other ImproX units via the RS485 Terminal Bus using the ImproX Secure Communications Protocol INSTALLATION ...

Страница 7: ...ounting surface and insert wall plugs if required 3 Mount the unit to the mounting surface 4 Remove the two screws holding the lid to the unit and remove the lid 5 Pull the wires through the cable glands 6 Connect the wires to the terminal blocks on the PCB The required connections are described under Connecting the Unit 7 Replace the lid and hold it in place with the two screws Remote Type Select...

Страница 8: ...ust be remembered that the Tx terminal on the ImproX DT Terminal must be connected to the Rx terminal on the Remote Reader and vice versa It is recommended that the cable screen be connected to the Remote Unit 5V Out terminal at the ImproX DT Terminal and to the POWER terminal at the Remote Reader as shown in Figure 2 For an Impro 4 Channel UHF Receiver connection the Remote Unit 5V Out terminals ...

Страница 9: ... Each ImproX unit is allocated a unique Fixed Address at the factory This address is stored in its memory When the unit is installed in a system the system allocates a separate Logical Address to the unit for communication purposes Fixed Address The unit s Fixed Address is recorded on a label attached to the back of the unit A copy of this label is attached to the packing box in which the unit is ...

Страница 10: ...the unit and an ImproX Unit Location Chart provided with every ImproX IC Controller or ImproX IL Computer A unique description of the unit s physical location must also be recorded on the Chart This process is described below 1 Remove the loose copy of the unit address label from the packing box and attach it to the ImproX Unit Location Chart in the Unit Fixed Address column 2 In the Unique Locati...

Страница 11: ...ontacts using a ground wire for the return Terminal Bus RS485 5V OUT COMMS REMOTE UNIT Tx Rx TB6 TB5 POWER COMMS REMOTE TERMINAL Tx Rx Side 1 Side 2 Line Termination Jumper CAUTION These terminals are POWER OUTPUT terminals DO NOT connect incoming power to these terminals as this can damage the unit and nullify the guarantee Maximum distance of the Remote Terminal from the ImproX DT is 20 meters N...

Страница 12: ...n the ImproNet User Manual For OEM Systems details of the appropriate procedure should be included in the system documentation Related information for OEM programmers is included in the ImproX Secure Communications Protocol document Once this procedure has been completed the Host PC will contain a record of the unit s Fixed Address its Logical Address and a unique description of the physical locat...

Страница 13: ...ceiver This range is continually being updated Please consult your Impro dealer for details of any additions to the range ORDERING INFORMATION The ImproX DT Terminal can only be ordered paired with a Remote Reader The ordering codes are as follows COMBINATION ORDERING CODE ImproX DT ImproX KR XKR900 1 0 GB XX ImproX DT ImproX MR XMR900 1 0 GB XX ImproX DT ImproX KHR XKR901 1 0 GB XX ImproX DT Impr...

Страница 14: ... July 2001 Impro Technologies Data subject to change without notice Page 14 NOTES ...

Страница 15: ... July 2001 Impro Technologies Data subject to change without notice Page 15 NOTES ...

Страница 16: ...e our service to you Thank you for choosing Impro products to implement your security or asset management systems Impro Technologies design and manufacture a wide range of technically advanced high quality reliable Access Control and Asset Identification and Management Systems Please contact your distributor to find out more about our products or advise us of your needs for specialised products no...

Отзывы: