Arc Suppression
Snubber devices are recommended for EMF Flyback and Arc Suppression when
driving an inductive load with the Relay, see Figure 2.
Figure 2: EMF Flyback and Arc Suppression
Installing the Real Time Clock (RTC) Backup Battery
CAUTION:
Remove the Battery Tab for the Real Time Clock from the Battery
Holder IMMEDIATELY BEFORE powering up the IXP20 Controller.
DO NOT remove the Battery Tab after applying power to the IXP20.
First Time Use
1.
Ensure that power is NOT applied to the Controller.
2.
Locate the removable Battery Tab.
3.
Pull the removable Battery Tab out of the Battery Holder.
4.
Immediately apply power to the Controller.
Replacement
NOTE:
Because of the delicacy of this procedure, we recommend you contact your
distributor before trying to replace the Battery.
Mounting the IXP20 Controller
CAUTION:
Make certain that you mount the Controller on a vibration-free
surface.
NOTE:
You can mount the IXP20 Controller onto virtually any surface including
metal.
Select the mounting position of the IXP20 Controller, considering accessibility, routing
of wires and visibility of the Thin Film Transistor Liquid Crystal Display (TFT-LCD) and
accessibility of the Keypad.
Secure the enclosure to the mounting surface, using four suitable screws and wall
plugs, nuts and bolts or rivets.
Содержание IXP20
Страница 12: ...ISC304 0 0 GB 06 April 2011 Page 12 Figure 5 IXP20 Controller connected to Wiegand Reader...
Страница 13: ...ISC304 0 0 GB 06 April 2011 Page 13 Figure 6 IXP20 Controller connected to ImproX RF...
Страница 16: ...ISC304 0 0 GB 06 April 2011 Page 16 Fixed Address Label Unique Location Description...
Страница 17: ...ISC304 0 0 GB 06 April 2011 Page 17 Fixed Address Label Unique Location Description...
Страница 18: ...ISC304 0 0 GB 06 April 2011 Page 18 Fixed Address Label Unique Location Description...