background image

 

IXP343-0-0-GB-07 

 

April 2009 

Page 9 

 

IXP110 System Maintenance 

Deleting the Database 

If it becomes necessary to clear all Tagholders, including all Tagholder settings, follow 
these steps:  

 

Figure 8:  Deleting the Database 

Restore Factory Defaults 

If it becomes necessary to return the IXP110 System to its factory default settings, 
follow these steps:  

 

Figure 9:  Restoring Factory Defaults 

 

Blank Space

 

 

 

Содержание IXP110

Страница 1: ...sing a Sealed Lead Acid Backup Battery and or Strike Lock 9 V AC to 18 V AC 9 V DC to 24 V DC NOTE Battery Charging Voltage and Power Output Voltage are set at between 13 6 V DC and 13 8 V DC NOTE Thi...

Страница 2: ...ng Input protection to 50 V DC continuous Figure 1 End of Line EOL Sensing Circuit NOTE These Inputs can be individually configured to have End of Line EOL Sensing in the Software via the Communicatio...

Страница 3: ...stors 25 Vrms 500 A 77 V max clamping Four Wood Screws 3 5 mm x 25 mm Four Wall Plugs 7 mm IXP905 1 0 GB XX includes a standard 2 m 7 ft USB Printer Cable The USB Cable will have a Type A plug fitted...

Страница 4: ...area of the cable must not be less than 0 2 mm 2 0 0003 in 2 NOTE When installing an ImproX RA use 1 pair twisted cable Cable Specifications The cable specifications should be similar to the following...

Страница 5: ...gs supplied nuts and bolts or rivets Top Cover Release Mechanism 1 Remove the top two Thread Cutter Screws 2 2 x 5 mm from each of the End Plates 2 Insert a flat head screwdriver maximum 7 mm into the...

Страница 6: ...r the metal clip of the Battery Holder with the Terminal facing UP 3 Press the Battery firmly into the Battery Holder 4 Attach the Controller s Top Cover Replacement 1 Remove the Controller s Top Cove...

Страница 7: ...IXP343 0 0 GB 07 April 2009 Page 7 Connecting the IXP110 Controller Figure 6 Input and Power Connections...

Страница 8: ...IXP343 0 0 GB 07 April 2009 Page 8 Figure 7 Antenna Reader and Relay Connections...

Страница 9: ...s necessary to clear all Tagholders including all Tagholder settings follow these steps Figure 8 Deleting the Database Restore Factory Defaults If it becomes necessary to return the IXP110 System to i...

Страница 10: ...ns including deleting the database and restoring factory defaults MAC Address The MAC Address identifies the Lantronix XPort component placed in each Ethernet version of the IXP110 Controller IXP906 1...

Страница 11: ...IXP343 0 0 GB 07 April 2009 Page 11 USER NOTES...

Страница 12: ...mproX IXP110 Controller IXP904 1 0 GB 02 IXP905 1 0 GB 02 and IXP906 1 0 GB 03 The last two digits of the Impro stock code indicate the issue status of the product IXP343 0 0 GB 07 Issue 08 Apr 2009 I...

Отзывы: