XTT300-0-0-GB-16 

January 2011 

Page 4 

 

Power Supply Combo (IPS910) 

 

An ImproX (TT) Twin Antenna Terminal housed in a Black Mild Steel, powder-
coated Cabinet.  The Cabinet consists of a hinged Lid and a Base. 

 

Three Metal-oxide Varistors, 25 Vrms, 500 A, 77 V max clamping. 

 

A glass Fuse, Slow Blow, 3.15 A, 250 V (5 mm x 20 mm). 

 

Four Combi Screws (No. 4 x 10 mm). 

 

An extra Fixed Address Label. 

You will find the following when unpacking the optional extra Security Accessory Pack 
(XTT911-0-0-NN-XX): 

 

Two TORX® Fasteners (M3.5 x 10 mm). 

 

A T10 TORX® Key. 

General 

Remember the following when installing the ImproX TT Terminal: 

Communications Distance 

The RS485 communications distance between the first ImproX TT and the LAST 
ImproX unit in a cable run, MUST NOT exceed 1 km (1 090 yd).  Achieve this by using 
good quality screened twisted 2-pair cable, with the screen EARTHED at one end. 

Jumper Links 

Long transmission lines or multiple “star” connections, may cause communication 
problems.  Placing a Jumper Link across the jumper [TR1] in the LAST UNIT AT THE 
END OF THE CABLE RUN should solve the problem.  See Figure 6 for the location of 
the jumper [TR1]. 

Antenna Reader Distance 

The ideal cable distance between the ImproX TT and its Antenna Reader ranges 
between 2 m to 16 m (7 ft to 53 ft).  Optimal performance is not guaranteed outside of 
this range.  Achieve optimal performance using good quality screened, twisted pair 
cable. 

Distance between Antenna Readers from the SAME Terminal 

To avoid mutual interference, install the Antenna Readers alongside each other at least 
150 mm (6 in) apart. 

Distance between Antenna Readers from DIFFERENT Terminals 

To avoid mutual interference, install the Antenna Readers alongside each other at least 
500 mm (20 in) apart. 

NOTE: 

ImproX TT Terminals can be mounted alongside each other. 

EARTH Connection 

Connect the ImproX TT Terminal to a good EARTH point.  Using the RS485 Port, 
connect the EARTH Lead to the „

‟ Terminal.  Mains EARTH can be used, but 

electrical noise may exist. 

Содержание IMPROX TT

Страница 1: ...nment Open Frame Construction XTT900 Designed to work in an indoor dry environment The Terminal is not sealed against water Aluminium Extruded Cabinet XTT910 Designed to work in an indoor dry environm...

Страница 2: ...ort circuit Overcome this by installing the recommended 12 V 7 Ahr Battery to help supplement the in rush current such a device may draw on activation Power Input Input Voltage 85 V AC to 265 V AC at...

Страница 3: ...ashing Green LED Outgoing RS485 Data Flashing Red LED Digital Inputs 1 4 Continuous Green on detected contact closure Relays 1 and 2 Continuous Red on activation of the Relay INSTALLATION INFORMATION...

Страница 4: ...lines or multiple star connections may cause communication problems Placing a Jumper Link across the jumper TR1 in the LAST UNIT AT THE END OF THE CABLE RUN should solve the problem See Figure 6 for...

Страница 5: ...into the Cabinet with the Battery Terminals in an upwards position 4 Connect the Red Battery Terminal Lead to the Positive Battery Terminal 5 Connect the Black Battery Terminal Lead to the Negative Ba...

Страница 6: ...the two End Plates Swivel the screwdriver until the Top Cover makes a click sound 4 Insert the screwdriver in the gap on the side of the ImproX TT between the Top Cover and the Base Swivel the screwdr...

Страница 7: ...nuary 2011 Page 7 Use the supplied Connection Leads for the low voltage connections to the Power Supply Combo Using the supplied Quick Click Glands or Gland Breakouts neatly lead the wires out of the...

Страница 8: ...XTT300 0 0 GB 16 January 2011 Page 8 ELECTRICAL CONNECTIONS Power Supply Combo IPS910 Layout Figure 5 Layout Diagram Power Supply Combo...

Страница 9: ...0 0 GB 16 January 2011 Page 9 Connecting the ImproX TT Terminal Figure 6 shows a detailed electrical connection diagram for the ImproX TT Terminal Figure 6 Typical ImproX TT Terminal Electrical Conne...

Страница 10: ...AT RISK OF ELECTRICAL SHOCK CAUTION DO NOT exceed the Input Voltage specified Wiring the Mains Input Power Cord WARNING DO NOT TOUCH ANY PART OF THE CIRCUIT ONCE YOU VE APPLIED POWER TO THE POWER SUPP...

Страница 11: ...Slow blow 5 mm x 20 mm Table 1 Fuse Ratings NOTE Because of the delicacy of the replacement procedure we recommend you contact your distributor before trying to replace the Power Supply Fuse Replacin...

Страница 12: ...he ImproX TT will then reveal only one Fixed Address In all other arrangements the Terminal reveals two Fixed Addresses Address Allocation IXP220 IXP300 and IXP400 Systems IXP Software Suites allocate...

Страница 13: ...XTT300 0 0 GB 16 January 2011 Page 13 USER NOTES...

Страница 14: ...XTT300 0 0 GB 16 January 2011 Page 14 USER NOTES...

Страница 15: ...XTT300 0 0 GB 16 January 2011 Page 15 USER NOTES...

Страница 16: ...T Twin Antenna Terminal XTT900 1 0 GB 05 XTT910 1 0 GB 03 IPS910 1 0 GB 02 and XTT911 0 0 NN 00 The last two digits of the Impro stock code indicate the issue status of the product XTT300 0 0 GB 16 Is...

Отзывы: