3 - Installation
3.1 General instructions for the installation
Before the installation, the qualified and trained personnel must read this
manual and wear personal protective equipment (PPE) such as safety
glasses (scale number 2, 2C or 3 according EN166), gloves, etc…
Before proceeding with the installation, make sure that all the components are unpacked and not
damaged.
Installation and commissioning must be carried out by qualified and trained personnel only and in
observance for the local laws.
3.2 Positioning of the appliance
ELITURBO UV-LIGHT
®
must be installed at minimum height of
2
,
5
meters from the floor.
In presence of accessible mezzanine, check that
the appliance is positioned at a safety distance not lower than 2,5 m from the
mezzanine floor.
UV radiation may cause severe damages to eye and skin, even in low doses.
Before positioning the appliance, identify the point of its installation and check that it does not
interfere with any system / device or mean used for lifting loads in normal work operations (lifters,
jib cranes, lamps, etc.).
It is recommended to hang the appliance from the ceiling, or from a beam, and to perform a
structural
analysis of the identified installation support, in order to avoid any risk of falling of the appliance.
Hang from the ceiling by means of steel chain with wire diameter not less than 3,5 mm or by means
of adequately sized steel cords.
As general rule,
supporting devices must be capable of withstanding a mass equivalent to 5 times the mass of the
appliance distributed over the attachment points (see chapter 2 – Product specifications)
Make sure that the appliance is installed perfectly horizontal.