Impresind E.L.C. 2000 Скачать руководство пользователя страница 8

 

Y

ELITURBO SYSTEM 

Section 2 – Packing, logistic and transport 

 

SECTION 2 – PACKING, LOGISTIC AND TRANSPORT 

2.1 Equipment receiving 

 

When the package is delivered to the client, the latter is obliged to control the integrity of the 
product. 
 

 

 

 
 
 
 
 

2.2 Logistic and transport 

 

 

 

 

Control the package an its contents, in case of
damage due to the transport, the client has to

tick damage claim box on the transport
document, counter signed by the carrier and
send a copy via fax to Impresind Srl. 

Pay high attention in handling the Eliturbo

®

 units during the phases of:

downloading from the carrier, logistics and positioning, to avoid damages to
the unit. 

  

 

IMPRESIND SRL DECLINES ANY RESPONSABILITY FOR DAMAGES
DUE TO TRANSPORT, UPLOAD, DOWNLOAD OF THE ELITURBO

®

UNITS 

 

 
Move Eliturbo

®

 units with maximum care, avoid to interfere with the ventilator. 

2.3 Lifting 

 

Ensure that the maximum lifting power of the lifter is adequate to the
products weight. 
The product has to be lifted only by qualified personnel. 

 

 
 

 

IT IS ABSOLUTELY FORBIDDEN TO STAY UNDER THE HANGING
LOADS AND INSIDE THE ACTION AREA OF THE LIFTER 

 
 

It is suggested to handle the Eliturbo

®

 air mixer by the top supports avoiding

to interfere with the circular deflectors. 
Avoid touching with the hands the rotor: deformation danger and consequent
unbalanced functioning of the air mixer.

 

  

 

 

 

8  

IST. E101.101GB –- ed. 11/08 

Содержание E.L.C. 2000

Страница 1: ...Air Mixer User and maintenance guide Distribuitor CALOR SRL Str Progresului nr 30 40 sector 5 Bucuresti tel 021 411 44 44 fax 021 411 36 14 www calorserv ro www calor ro...

Страница 2: ...ge 9 SECTION 3 INSTALLATION AND TESTING 10 3 1 General warnings for installation 10 3 2 Positioning the Eliturbo 10 3 3 Electric network connection 12 SECTION 4 PROTECTION SYSTEMS 15 4 1 Protection de...

Страница 3: ...This guide has to be conserved until the final dismantling of the product in case of property change the guide has to be delivered to the new owner In case of damage and consequent block of the produc...

Страница 4: ...and on the cover of the guide The product is in accordance with the following community directives 2006 42 CE Machine Directive 2006 95 CE Low Voltage Directive 2004 108 CE Electromagnetic Compatibil...

Страница 5: ...t bother workers it is manufactured in accordance with the security norms and the environment s hygiene norms The Eliturbo air mixer differing from the other ceiling ventilators doesn t direct air flu...

Страница 6: ...licentrifugal Fan type 2 Rotor version n blades 2 4 Treated air m3 h 7500 10000 Speed Rpm 700 Diameter mm 680 Height mm 570 Weight kg 16 18 External finishing Epoxy powder paint Colour black Table 1 T...

Страница 7: ...ELY FORBIDDEN TO MODIFY THE SWITCHBOARD IT IS ABSOLUTELY FORBIDDEN TO ESTINGUISH FIRES WITH WATER 1 7 Improper use The unit can t be used for different scopes than the ones stated in the paragraph 1 3...

Страница 8: ...rrier logistics and positioning to avoid damages to the unit IMPRESIND SRL DECLINES ANY RESPONSABILITY FOR DAMAGES DUE TO TRANSPORT UPLOAD DOWNLOAD OF THE ELITURBO UNITS Move Eliturbo units with maxim...

Страница 9: ...anger of fire and suffocation of people or animals The discharge of the packaging material has to be done in specification to the norms in force in the destination Country of the Eliturbo 2 5 Storage...

Страница 10: ...ified by different colour arrows applied on the unit and the packaging Clockwise rotation Anti clockwise rotation When installing it is important to follow a chess board global positioning of the unit...

Страница 11: ...s as lifters kranes etc Avoid positioning the unit near scaffolding racks etc In case of accessible scaffolding verify that the unit is positioned at least 2 5m from the scaffolding To anchor the unit...

Страница 12: ...e to be certified Before operating on the power cables ensure that the network was severed Ensure an efficient connection of earthing using the specific terminals The foreseen power is 230 V 50 Hz For...

Страница 13: ...right hand clockwise V 230 50 Hz CAPACITOR CHECK VALUE ON PLATE LABEL ON ENGINE V2 W2 U2 W1 U1 V1 L3 L1 L2 V 400 50 Hz TO REVERS THE ROTATION EXCHANGE PHASES L1 L2 left hand anticlockwise capacitor C...

Страница 14: ...he Technical Assistance of Impresind Srl do not start the product if is shows any of the anomalies stated above To invert the direction of rotation of the engine after cutting off the electric power t...

Страница 15: ...g prescription for the personnel The maintenance personnel are obliged to wear specific clothing and to use personal protection devices 4 3 Residual risks Pay attention to the movement of the ventilat...

Страница 16: ...to work constantly to contrast the natural elevation of hot air to the ceiling For a better management of the system and to achieve energetic savings it is necessary that the heating system has an env...

Страница 17: ...are visible by all access areas Record on a register all the maintenance carried out making sure to sign date hour type of maintenance and name of the personnel that carried out the maintenance The e...

Страница 18: ...WITH THE SECURITY SYSTEMS DEACTIVATED OR DISCONNECTED DEACTIVATE OR TRICK THE ALARM SIGNALS APPLIED ON THE PRODUCT USE THE PRODUCT WITH THE METALLIC PROTECTIONS REMOVED IGNORE THE WARNINGS AND SIGNS A...

Страница 19: ...alised personnel with correct instruments and personal protection devices Do not smoke and not use free flames In case of dismantling or alienation of the system it is necessary to recover all the mat...

Отзывы: