The
‘Load From Factory’
command instructs the camera to load its
workspace from the factory space. All current workspace settings will be
replaced with the contents of the factory space. This is a command, not a
register. The act of writing to this location initiates the load from the factory.
Address
:
0x6060
4.3.2.3 Load From User #1
The
‘Load From User #1’
command instructs the camera to load its
workspace from the user #1 space. All current workspace settings will be
replaced with the contents of the user #1 space. This is a command, not a
register. The act of writing to this location initiates the load from the user #1.
Address
:
0x6064
4.3.2.4 Load From User #2
The
‘Load From User #2’
command instructs the camera to load its
workspace from the user #2 space. All current workspace settings will be
replaced with the contents of the user #2 space. This is a command, not a
register. The act of writing to this location initiates the load from the user #2.
Address
:
0x6068
4.3.2.5 Load MFG Default Gain
The
‘Load MFG Default Gain’
command instructs the camera to load its
default gain and offset settings from the manufacturing space. Different
settings will be loaded for “slow” and “fast” camera speed. This is a
command, not a register. The act of writing to this location initiates the load
the default gain and offset settings.
Address
:
0x606C
4.3.2.6 Save to User #1
The
‘Save To User #1’
command instructs the camera to save its
workspace to the user #1 space. All current workspace settings will be saved
to the user #1 space. This is a command, not a register. The act of writing to
this location initiates the save to user #1 space.
Address
:
0x6074