Страница 1: ...have read this manual and are familiar with the function of the equipment Service of the equipment should be performed by qualified personnel who are knowledgeable with Imperial Ranges WARNING Imprope...

Страница 2: ...ING The installation of the fryer must conform with local codes or in the absence of local codes with the National Fuel Code ANSI Z223 1 NFPA 54 the National Gas Installation Code CSA B149 1 as applic...

Страница 3: ...that complies with the standard for quick disconnect devices for use with Gas Fuel should comply with ANSI Z21 41 and addendum Z721 41a or latest edition If disconnection of the restraint is necessary...

Страница 4: ...ON position Turn thermostat to desired temperature setting DAILY SHUT DOWN At the end of the day turn the gas cock dial on the combination gas valve and the thermostat to OFF position Where applicable...

Страница 5: ...the thermometer 4 If the temperature differential between the thermostat and the thermometer is more that 5 F recalibrate the thermostat CALIBRATING 1 Pull the thermostat knob out Use a screwdriver to...

Страница 6: ...bracket Reverse the procedure to install FOR SERVICE OR ORDERING PARTS Have the following information ready before contacting for service or ordering 1 Model number and serial number of the fryer 2 Ty...

Страница 7: ...perature E Defective gas valve E Replace F Defective hi limit switch F Replace Fryer does not heat up A Insufficient gas A Check gas pressure B Line clogged B Remove and clean gas line C Overloading t...