Economy Series Installation Details:  

 

CABINET: 

Be sure that the cabinet bottom is level, side to side and front to rear.  

For the Vented Unit (1900E) you will need to cut an  8” x  8” hole in the bottom of the cabinet, 3/4” in from 
the rear wall and on center line.  For the Non-Vented model (1900ENV) there is no need for a duct pipe cut 
out.  Shelves and top to be cut to clear 7” round pipe to line up with the bottom cabinet cut out.   
Also, cut holes for electrical wires for both Vented and Non-Vented.   
 

ELECTRICAL: 

Stub enough wire into cabinet to reach in front of vent pipe.  Enter cabinet 3 1/4” left of 

center and 1 1/2” from wall for vented and non-vented units.  Remove splice box cover before mounting 
hood.   
 

NOTE: 

Be sure to remove black electrical tape that holds the damper blades closed. 

 

MOUNTING:  

Insert canopy below the cabinet, being sure your vent opening and electrical cut outs line 

up with cabinet cut outs.  Use the Key Hole mounting holes to secure the canopy.  After hood is mounted 
attach house wires to leads in the hood.  Secure locknut to conduit and check wiring for compliance to local 
building codes. 
 

FINISH: 

Replace splice box cover.  Connect duct and tape all joints. Replace Filter. 

 

WARNING: 

To reduce the risk of fire or electrical shock DO NOT use the “E” series with any solid-state speed control 
device. 