Imperial Cal Products, Inc. 

 
 
 

 

Read Before Starting Installation! 

Inspect your range hood prior to installing! 

 Any cosmetic defects must be reported to us prior to installation. 

Once this hood is installed, ICP will NOT accept any responsibility 

 for any cosmetic blemishes, scratches or dents in the Canopy. 

Save all original packaging if you wish to return for any reason! 

 

FIRST: 

Check your local building and electrical codes.   
 

WARNING: 

 

To reduce the risk of fire or electrical shock, Do Not use any two speed motor units with a Solid 
State control devise. 
 

CAUTION:  

To reduce the risk of fire or personal injury and to properly exhaust air, be sure to duct air  to the 
outside.  DO NOT vent exhaust air into spaces within wall, attics, ceilings, crawl spaces or       
garages.  When venting to the outside make duct run as short and straight as possible.   

Avoid using elbows if at all possible as this will reduce your performance.  

Every elbow will 

decrease the performance and we will not guarantee the effectiveness of the range hood. 
 

No Performance Warranty when used above BBQ Style Grills.      

 

 
DO NOT use duct pipe smaller than the outlet duct opening on the hood, this will reduce  
performance and void the warranty.  DO NOT use flex ducting.  Also, use either a Roof Cap or 
Wall Cap to end run.  Be sure that all joints are taped securely in place. It is essential to have the 
proper distance between the bottom of the range hood and the cooking surface below. In most 
cases the cooking appliance manufacturers specifications will establish the fire safe minimum 
distance required, although there are other factors to consider: 



Local Building Codes 



Cross directional air movements ie: open windows,  air conditioning/heating outlets, cooling 
fans, etc. 



Overall size of the cooking appliance and surrounding countertop surfaces. 



Range hood model selected. 

 
For best performance distance between cooking surface and the bottom of the hood is 30” and 
36”.  Check local codes and appliance specifications. Keep in mind, increasing the distance will 
decrease the performance.  

 

THERMOSTAT: PS or BP 

Units ONLY.  When cooking surface reaches 130 degrees, the unit will 

automatically turn ON to the highest setting and won’t be able to be turned off until the area has 
cooled down.  For safety, it’s best to have unit on while cooking. (This thermostat will NOT prevent 
fires.  Fires are most often cause by excessive grease build up.) 
 

TWIN UNITS ONLY - 

Transitioning two pipes into one is NOT recommended. CFMs are reduced 

by 25% and the Performance Warranty will be void.  
 

 

 
  

Содержание C2030PSSB-IS22-SS

Страница 1: ...LNR 7 17 Powered Liner C2000 Installation Instructions Warranty Information 425 Apollo Street Brea CA 92821 www imperialhoods com 800 851 4192 DO NOT THROW AWAY PROPERTY OF THE HOME OWNER ...

Страница 2: ...uce performance and void the warranty DO NOT use flex ducting Also use either a Roof Cap or Wall Cap to end run Be sure that all joints are taped securely in place It is essential to have the proper distance between the bottom of the range hood and the cooking surface below In most cases the cooking appliance manufacturers specifications will establish the fire safe minimum distance required altho...

Страница 3: ...ded 4 If required additional mounting at the rear of the unit Locate wall studs drill holes through back of insert to hit studs and attach the liner to the wall with screws 5 Island and Peninsula liners should be mounted in the same way except there will be no rear wall mount 6 Bring conduit down 4 past the bottom of the liner NOTE Top box for the C2000BP1 shows vent opening Off Set to the left fa...

Страница 4: ...e cut out opening Figure 3 Figure three shows a typical air exit terminating through the soffit face directly above the hood canopy Again the customer must provide a 4 x 10 register face plate Re Circulating Non Vented Series C2000SD2 NV For use when unable to terminate exhaust ducting to outside the structure NOTE The C2000 NV Unit comes supplied with charcoal filters that will accumulate the coo...

Страница 5: ...l need the exact dimensions of the filter needed Indicate which side has the pull tabs on it Filters are not a warranty replacement part With care your filters should last many years Payment on Parts is handled one of three ways PrePaid you send a check prior to our Shipping call with credit card information VISA or MasterCard COD or Cash if you decide to Will Call Our Will Call hours are 8 30 to ...

Страница 6: ...obtain service under warranty Deluxe Units Seven Year Limited Warranty Parts and Labor in the Continental USA Parts only outside the United States For seven years from date of original purchase we will provide parts and service labor in your home to repair or replace any part of the hood that fails due to a manufacturing defect Call for service at 800 851 4192 NOTE Service companies will perform W...

Страница 7: ...ie sheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS If flames do not go out immediately EVACUATE AND CALL THE FIRE DEPARTMENT B NEVER PICK UP A FLAMING PAN you may be badly burned C DO NOT USE WATER including wet dishcloths or towels violent steam explosion will result D Use an extinguisher ONLY if You know you have a Class ABC extinguisher and you already Know how to use i...

Страница 8: ...Liner alimenté C2000 Instructions d installation Informations sur la garantie 425 Rue Apollo Brea CA 92821 www imperialhoods com 800 851 4192 PROPRIÉTÉ DU PROPRIÉTAIRE DE LA MAISON NE PAS JETER ...

Страница 9: ...us ne recommandons vivement aucuns plus puis exécutez deux coudes de 90 degrés dans n importe quel canal Aucune garantie de Performance lors de l utilisation au dessus des grilles de Style BBQ N utilisez pas conduit plus petite que la sortie du conduit d ouverture sur le capot cela réduira les performances et annuler la garantie N utilisez pas de conduits flexibles Aussi utilisez soit un capuchon ...

Страница 10: ...ssaire supplémentaires de montage à l arrière de l appareil localiser les montants du mur percez les trous arrière de puissance suffisante pour frapper les goujons et fixez la toile au mur avec des vis 5 Doublures de l île et la péninsule doivent être montés de la même manière sauf qu il n y aura pas de montage paroi arrière 6 Conduit Bring down 4 passé le fond de la cocotte Remarque Top box pour ...

Страница 11: ...sortie d air typique se terminant par le visage de soffite directement au dessus de la hotte Encore une fois le client doit fournir une plaque frontale de Registre 4 po x 10 po NOTE L unité de NV C2000 est fournie avec des filtres à charbon qui sera accumuler de la graisse de cuisson et au fil du temps réduire la performance de hottes Le montant et le style de la cuisine vont dictera combien de fo...

Страница 12: ...s devrons les dimensions exactes du filtre nécessaire Indiquer de quel côté a les tirettes sur elle Les filtres ne sont pas une pièce de rechange de garantie Avec soin vos filtres doivent depuis plusieurs ans Paiement sur pièces est assurée de trois façons prépayé vous envoyez un chèque avant l expédition appelez avec informations de carte de crédit VISA ou MasterCard morue ou argent comptant si v...

Страница 13: ...aux USA conti nentaux Pièces uniquement en dehors des États Unis Pendant sept ans à compter de la date d achat initiale nous fournirons des pièces et la main d œuvre service à votre domicile pour réparer ou remplacer toute partie de la hotte qui échoue en raison d un défaut de fabrication Appel de service au 800 851 4192 REMARQUE Sociétés de services effectuera le Service sous garantie lundi au ve...

Страница 14: ...ie de graisse respectez les points suivants Étouffez les flammes avec un couvercle hermétique une tôle à biscuits ou un plateau métallique puis éteignez le brûleur VEILLEZ À ÉVITER LES BRÛLURES Si les flammes ne vont pas sortir immédiatement évacuer et appeler les pompiers Ne prenez jamais un poêlon vous pourriez vous brûler gravement N utilisez pas d eau mouillés ou serviettes explosion de vapeur...

Страница 15: ......

Страница 16: ...________________ MODEL __________________________________________________________ SERIAL ___________________________________________________________ Serial beneath filters on white label Warranty card can be submitted via our website at www imperialhoods com or by mail Please keep receipt Proof of original purchase date is needed to obtain service under warranty Mail warranty card to Imperial Cal ...

Отзывы: