background image

Read the following notices and information carefully to ensure proper operation of your air 

conditioner unit.

This manual is solely provided for informational purposes and in no way constitutes a legally 

binding document between the manufacturer, distributor, and end consumer. Exact appear-

ance of your unit may differ from the pictures and diagrams enclosed. 

Lea las siguientes indicaciones cuidadosamente para asegurar el correcto funcionamiento 

de su unidad de aire acondicionado. 

Este manual se proporciona únicamente con fines informativos y de ninguna manera 

constituye un documento jurídicamente vinculante entre el fabricante, distribuidor y 

consumidor final. apariencia exacta de su unidad puede diferir de las imágenes y esque-

mas adjuntos.

WARNING:

To avoid permanent damage to unit:

Ensure it is in the upright position for a MINIMUM of 6

hours and a RECOMMENDED time of 24 hours before pow-

ering on the first time.

ADVERTENCIA

Para evitar daños permanentes a la 

unidad:

Asegúrese de que está en la posición vertical durante

un mínimo de 6 horas y un tiempo recomendado de 24 

horas antes de encender la primera vez.

Содержание IWA10-QS30

Страница 1: ...Window Air Conditioner User Manual Aire acondicionado Manual de usuario Models IWA10 QS30 IWA12 QS30 www impecca com...

Страница 2: ...de aire acondicionado Este manual se proporciona nicamente con fines informativos y de ninguna manera constituye un documento jur dicamente vinculante entre el fabricante distribuidor y consumidor fi...

Страница 3: ...duction 6 Getting to Know Your Air Conditioner 7 Using your Air Conditioner 8 Remote Control 9 Pre Installation Instructions 11 Installing Your Unit 13 Energy Saving Panel Installation 16 Cleaning Mai...

Страница 4: ...ed repair It may cause fire and electric shock It may cause electric shock Ensure the power cord is kept away from any heating sources Do not disassemble or modify unit Do not use the power cord near...

Страница 5: ...d cause damage personal injury or death Operation with dirty filters or without filters will effect performance and may cause damage to the unit Do not use strong detergent such as wax or paint thinne...

Страница 6: ...objects Do not pull or yank the power cord to unplug the unit or move the air conditioner Do not insert or unplug the power plug with wet hands Only use a grounded power outlet Make sure the groundin...

Страница 7: ...tructing objects During operation close doors and windows to improve cooling effect Please put the air conditioner at smooth and flat ground for operation to avoid noise and vibration Do not tilt or t...

Страница 8: ...red room temperature by pressing the appropriate but ton Temperature changes are displayed in 1 increments in the range of 61 F 16 C to 86 F 30 C Note Temperature can not be set when using the fan mod...

Страница 9: ...tive button to increase or decrease fan speed AUTO BUTTON Press this button for an automatically adjusting fan speed based on ambient room tem perature Note To exit the AUTO function press the FAN but...

Страница 10: ...in plugged in for the timer to function properly REPLACING THE REMOTE CONTROLLER BATTERIES 1 Press gently on the tab located on the back side of the remote control unit Slide open the bat tery compart...

Страница 11: ...y be attached 5 Foam sash seal no adhesive 6 Foam seal with adhesive 7 Window Base Foam seal with adhesive 8 R1 Foam seal for window filler panels Energy Star 9 Upper Rail Screws x4 10 Screws x6 11 Fr...

Страница 12: ...nward and will not properly drain Perform these modifications to ensure proper operation of your unit If you have a standard window skip this step 1 Cut a 2 thick piece of wood to the length of the in...

Страница 13: ...ews included to attach the upper rail to the pre drilled holes on the top of the cabinet as shown in the graphic Ensure that the higher part of the rail is facing the front of the air conditioning uni...

Страница 14: ...THE WINDOW FRAME 1 With the help of another person center the unit on the windowsill The lower rail should be com pletely flush with the windowsill Gently lower the window until it holds the upper rai...

Страница 15: ...ing passersby use one type C screw to fasten the security bracket to the window If your window frame is plastic PVC fasten the bracket to the side of the window frame Detail 1 If your window is made o...

Страница 16: ...width of your finished filler panels on either side W and write it down It is important that you wait until you re completely done the instal lation as the width will vary depending on how you install...

Страница 17: ...r Clean the filter and unit casing Remove dust and other objects on the unit Discard any accumulated water inside the unit see section about drainage Removebatteriesfromtheremotecontrollertopreventcor...

Страница 18: ...and completely dry re insert the filter and close the filter cover by pressing firmly Note To avoid deformation and fire risk never dry the filter with a heat source such as a hair dryer fireplace or...

Страница 19: ...r The unit emits a strange smell This may be caused by residue from cooking and cigarette smoke etc that re main in the air conditioning unit Eliminated the source of the smell and clean the filter Th...

Страница 20: ...on E5 Over current protection Unplug and restart your unit to clear the error If the error persists contact a qualified service technician E6 Unplug and restart your unit to clear the error If the err...

Страница 21: ...NOTES...

Страница 22: ...NOTES...

Страница 23: ...Aire acondicionado Manual de usuario Modelos IWA10 QS30 IWA12 QS30 www impecca com...

Страница 24: ...OSE CON SU UNIDAD DE AIRE ACONDICIONADO 25 USANDO SU UNIDAD DE AIRE ACONDICIONADO 26 CONTROL REMOTO 27 INSTRUCCIONES DE PRE INSTALACI N 29 INSTALANDO SU UNIDAD 30 LIMPIEZA Y MANTENIMIENTO 32 SOLUCI N...

Страница 25: ...o darle mantenimiento a la unidad de aire acondicionado ap guelo y descon ctelo Aseg rese que el cable de suministro de energ a no est torcido doblado u opri mido bajo objetos pesados o filosos Para...

Страница 26: ...acondicionado debe ser operada dentro de un rango de tempe ratura de 62 F a 95 F 16 C a 35 C Se debe dejar un per metro de 12 30 cm libre de objetos alrededor del aire acondicionado No opere el aire...

Страница 27: ...AMILIARIZ NDOSE CON SU UNIDAD DE AIRE ACONDICIONADO 1 2 3 4 5 7 6 1 Gu a superior 2 Salida del aire fr o 3 Cuchillas direccionales de aire fr o 4 Entrada de aire c lido 5 Cable de suministro de energ...

Страница 28: ...deseada en la habita ci n al presionar el bot n adecuado Los cambios de temperatura se reali zan en pasos de 1 en el rango de 61 F 16 C a 86 F 30 C NOTA no es posible fijar la temperatura en los modo...

Страница 29: ...habitaci n y una opera ci n m s eficiente de la unidad BOTONES DE TEMPERATURA Ajuste la temperatura deseada en la habitaci n al presionar el bot n adecuado Los cam bios de temperatura se realizan en p...

Страница 30: ...eamente para desactivar el bloqueo del con trol remoto CAMBIO EN LA UNIDAD DE LA TEMPERATURA C O F 1 Cuando la unidad est apagada presione simult neamente el bot n y el bot n MODE para cambiar la unid...

Страница 31: ...selladora no adhesiva 4 Tira selladora adhesiva 5 Tornillos x6 6 Seguro para el marco 7 Soportedeseguridadparalaventana 8 Control remoto 9 Bater as del control remoto 2xAAA 10 Manual de Usuario 1 2 3...

Страница 32: ...derade2 deltama oigualalanchointeriordelaventana 2 Verifique que la madera est nivelada con o hasta 0 5 1 cm m s alta que el mar co exterior resistente a la intemperie 3 Asegureeltramodemaderaalalfeiz...

Страница 33: ...el riel gu a superior Permita un ngulo de inclinaci n ligeramente hacia abajo y atr s de aproxima damente 5 3 para que pueda drenar la condensaci n que se forma durante el funcionamiento del aire acon...

Страница 34: ...C para colocar el seguro a la ventana Si su marco de la ventana est echo de madera coloque el seguro a la ventana Detalle 1 Si el marco de la ventana es de pl stico PVC coloque el seguro a un lado de...

Страница 35: ...u unidad de aire acondicionado en los c lidos meses del verano siem pre realice las siguientes verificaciones para asegurar una operaci n confiable y eficiente Revise que en las entradas y salidas de...

Страница 36: ...instrucciones espec ficas de desecho de aparatos electrodom sticos Si su unidad a n funciona y est en buen estado en lugar de deshacerse de ella d nela a alguna instituci n de caridad LIMPIANDO EL CHA...

Страница 37: ...inmediato despu s de apagarlo La unidad no puede reiniciar sino hasta despu s de 3 minutos de que ha sido apagada para permitir que el condensador se enfr e y evitar el riesgo de incendio Espere unos...

Страница 38: ...rese que el control remoto cuenta con pilas tiles y frescas Hay humedad en la salida de aire Los ambientes de alta humedad pueden causar condensaci n en la salida del flujo de aire Con una esponja li...

Страница 39: ...ersiste contacte a un t cnico de servicio calificado F1 Falla de la unidad Contacte a un t cnico de servicio calificado F2 Falla de la unidad Contacte a un t cnico de servicio calificado H1 Estado de...

Страница 40: ...2016 Impecca a division of LT Inc Wilkes Barre PA...

Отзывы: