TROUBLESHOOTING TIPS:
Problem
What to Check
Unit does not start
• Make sure the dehumidifier plug is pushed completely into the outlet.
• Check the house fuse/circuit breaker box.
• Dehumidifier has reached its preset level or bucket is full.
• Reservoir is not in the proper position.
• Make sure three minutes have elapsed from time unit has been powered
on.
Dehumidifier does not dry
the air as it should
• Did not allow enough time to remove the moisture.
• Make sure there are no curtains, blinds or furniture blocking the front or
back of the dehumidifier.
• The humidity control may not be set low enough.
• Check that all doors, windows and other openings are securely closed.
• Room temperature is too low, below 41°F (5°C).
• There is a kerosene heater or something giving off water vapor in the
room.
The unit makes a loud noise
when operating
• The air filter is clogged.
• The unit is tilted instead of upright as it should be.
• The floor surface is not level.
Frost appears on the coils
• This is normal. The dehumidifier has an auto–defrost feature.
Water on floor
• Hose to connector or hose connection may be loose.
• Even though you’re using the reservoir, the back drain plug is open.
DISPLAY:
Shows the set % RH (Relative Humidity level) from 35% to 85% or auto start/stop time (0-24) while setting,
then returns to show the actual (+/-5% accuracy) room humidity level in a range of 30% RH to 90%RH.
DISPLAY ERROR CODES AND PROTECTION CODES:
AS
) Humidity sensor error—Unplug the unit and plug it back in. If error repeats, call for service.
ES
) Temperature sensor error—Unplug the unit and plug it back in. If error repeats, call for service.
P2
- Reservoir is full or reservoir is not seated correctly—Empty the reservoir and replace it in the right posi
-
tion.
EC
) Unit malfunction—Please make sure whether the environment temperature is suitable for the stated tem
-
perature in the manual or not. If not, please operate the unit under the stated temperature. If the environ
-
ment temperature is suitable for the stated temperature, please call for service.