TROUBLESHOOTING TIPS:

Problem

What to Check

Unit does not start

• Make sure the dehumidifier plug is pushed completely into the outlet.

• Check the house fuse/circuit breaker box.

• Dehumidifier has reached its preset level or bucket is full. 

• Reservoir is not in the proper position.

• Make sure three minutes have elapsed from time unit has been powered 

on.

Dehumidifier does not dry 

 

the air as it should

• Did not allow enough time to remove the moisture.

• Make sure there are no curtains, blinds or furniture blocking the front or 

back of the dehumidifier.

• The humidity control may not be set low enough.

• Check that all doors, windows and other openings are securely closed.

• Room temperature is too low, below 41°F (5°C).

• There is a kerosene heater or something giving off water vapor in the 

room.

The unit makes a loud noise 

when operating

• The air filter is clogged.

• The unit is tilted instead of upright as it should be. 

• The floor surface is not level.

Frost appears on the coils

• This is normal. The dehumidifier has an auto–defrost feature.

Water on floor

• Hose to connector or hose connection may be loose. 

 

• Even though you’re using the reservoir, the back drain plug is open.

DISPLAY:

 

Shows the set % RH (Relative Humidity level) from 35% to 85% or auto start/stop time (0-24) while setting, 

then returns to show the actual (+/-5% accuracy) room humidity level in a range of 30% RH to 90%RH.

DISPLAY ERROR CODES AND PROTECTION CODES:

AS

) Humidity sensor error—Unplug the unit and plug it back in. If error repeats, call for service.

ES

) Temperature sensor error—Unplug the unit and plug it back in. If error repeats, call for service.

P2

- Reservoir is full or reservoir is not seated correctly—Empty the reservoir and replace it in the right posi

-

tion.

EC

) Unit malfunction—Please make sure whether the environment temperature is suitable for the stated tem

-

perature in the manual or not. If not, please operate the unit under the stated temperature. If the environ

-

ment temperature is suitable for the stated temperature, please call for service.

CONTACT CUSTOMER SUPPORT

Web: www.impecca.com
Email: [email protected] 
Phone: +1 866-954-4444

Содержание IDM-30SE

Страница 1: ...i Impecca Dehumidifier User s Manual IDM 30SE 30 Pint Dehumidifier IDM 45SE 45 Pint Dehumidifier IDM 70SE 70 Pint Dehumidifier...

Страница 2: ...or disposal at least free of charge to the user D As old products contain valuable resources they can be sold to scrap metal dealers Wild disposal of waste in forests and landscapes endangers your hea...

Страница 3: ...batteries and AC adaptors Impecca reserves the right to repair or replace defective products with the same equivalent or newer models We reserve the right to either repair or replace product at our d...

Страница 4: ...tacle is accessible after the unit installation Do not exceed the rating of the power outlet or connection device Do not operate or stop the unit by switching on or off the power Do not damage or use...

Страница 5: ...rd and take care so that the cord is not compressed Do not climb up on or sit on the unit It may cause electric shock or failure of appliance There is danger of fire or electric shock You may be injur...

Страница 6: ...aters or radiators Use the unit to prevent moisture damage anywhere books or valuables are stored The dehumidifier should be operated in an enclosed area to be most effective Close all doors windows a...

Страница 7: ...he unit may be completely silent 3 CONTINUOUS MODE In continuous mode the unit s compressor will run continuously until the unit is powered off or another mode is selected This will remove all the moi...

Страница 8: ...the reservoir you should wipe it dry CONTINUOUS DRAINAGE Water can be automatically emptied into a floor drain or any drain locat ed lower than the dehumidifier itself by attaching a standard garden...

Страница 9: ...minate This will provide a quicker dehumidification Ideal for situations where speedy removal of moisture is more important than quiet operation RESERVOIR FULL LIGHT Illuminates when the reservoir is...

Страница 10: ...an ing the reservoir must be in place and securely seated for the dehumidifier to operate CLEANING THE AIR FILTER Clean the filter every two weeks based on normal operating con ditions 1 Remove the re...

Страница 11: ...ears on the coils This is normal The dehumidifier has an auto defrost feature Water on floor Hose to connector or hose connection may be loose Even though you re using the reservoir the back drain plu...

Страница 12: ...2016 Impecca a division of LT Inc Wilkes Barre PA...

Отзывы: