INSTALLER
CHECK AFTER INSTALLATION
Check Items
Problems Owing to Improper Installation
Is the installation reliable?
The unit may drop, vibrate or make noises
Has the gas leakage been checked?
May cause unsatisfactory cooling (heating)
effect
Is the thermal insulation of the unit
sufficient?
May cause condensation and water dropping
Is the drainage smooth?
May cause condensation and water dropping
Does the power supply voltage accord
with the rated voltage specified on the
nameplate?
The unit may bread down or the components
may be burned out
Are the lines and pipelines correctly
installed?
The unit may bread down or the components
may be burned out
Has the unit been safely grounded?
Risk of electrical leakage
Are the models of lines in conformity
with requirements?
The unit may bread down or the components
may be burned out
Are there any obstacles near the air
inlet and outlet of the indoor and outdoor
units?
The unit may bread down or the components
may be burned out
Have the length of refrigerating pipe
and refrigerant charge amount been
recorded?
It is not easy to decide the charge amount
of refrigerant.
7
CUSTOMER SUPPORT
Before contacting customer support, please see the troubleshooting guide above.
Visit our website to contact us, find answers to Frequently Asked Questions, and for other
resources which may include an updated version of this user's guide.
WWW.IMPECCA.COM
If you wish to contact us by phone, please be sure to have your model number and serial
number ready and call us between 9:00am and 6:00pm ET, at +1 866-954-4440.
Keep tabs on Impecca's newest innovations & enter contests via our social network feeds:
www.facebook.com/Impecca/
www.instagram.com/impecca/
@impeccausa
© 2016 Impecca, a division of LT Inc., Wilkes Barre, PA.