4.

ALWAYS use the correct regulator. Each
regulator is designed to be used with a
specific gas.

5.

ALWAYS inspect the hose before use to
ensure it is in good condition.

6.

ALWAYS keep the free length of gas hose
outside the work area.

7.

ALWAYS remove all flammable materials
from the welding area.

8.

NEVER remove any of the panels unless the
machine is disconnected from the supply,
AND never use the machine with any of the
panels removed.

9.

NEVER attempt any electrical or mechanical
repair unless your are a qualified technician.
If you have a problem with the machine
contact your local IMPAX dealer.

10. NEVER use or store in a wet/damp

environment. DO NOT EXPOSE TO RAIN.

11. NEVER use gas from a cylinder, the content

of which is unknown. It is important to
ensure the appropriate gas is being used.

12. NEVER use a damaged cylinder.

13. NEVER lift the cylinder by the valve.

14. NEVER expose the cylinder to a heat source

or sparks.

15. NEVER continue to weld, if, at any time, you

feel even the smallest electric shock. Stop
welding IMMEDIATELY, and DO NOT
attempt to use the machine until the fault is
diagnosed and corrected.

16. NEVER use the welder with input

connections greater than 10M in length.

17. NEVER point the torch at any person or

animal.

18. NEVER touch the torch nozzle until the

welder is switched OFF and the nozzle has
been allowed to cool off.

19. NEVER connect, disconnect, or attempt to

service the torch, until the machine is
switched OFF and disconnected from the
mains supply.

20. NEVER allow the cables to become

wrapped around the operator or any person
in the vicinity.

21. Safety devices such as interlocks and circuit

breakers should not be disconnected or
shunted out.

22. Before installation, inspection, or service of

equipment, shut OFF all power and remove
line fuses to prevent accidental turning ON
of power.

23. Do not open power circuit or change

polarity while welding.

24. If, in an emergency, it must be

disconnected, guard against shock burns, or
flash from switch arcing. Always shut OFF
and disconnect all power to equipment.
Power disconnect switch must be available
near the welding power source.

25. Fully insulated electrode holders should be

used. Do NOT use holders with protruding
screws or with any form of damage.

26. Fully insulated lock-type connectors should

be used to join welding cable.

27. Frequently inspect cables for wear, cracks

and damage. IMMEDIATELY REPLACE
those with excessively worn or damaged
insulation to avoid possibly lethal shock
from bared cable. Cables with damaged
areas may be taped to give resistance
equivalent to original cable. Keep cable dry,
free of oil and grease, and protected from
hot metal and sparks.

Содержание IM-MMA130-IWK

Страница 1: ...bove is in conformity with the relevant statutory requirements 6 References to the relevant designated standards used or references to the other technical specifications in relation to which conformit...

Страница 2: ...Always Read Instruction Manual Retain for Future Reference IM MMA130 IWK 130A MMA WELDER...

Страница 3: ...dequately packed to prevent transit damage and must be accompanied with a brief description of the fault and a copy of the receipt or other proof of purchase The manufacturer shall not be liable for a...

Страница 4: ...onal injury CAUTION CAUTION without the safety alert symbol is used to address practices not related to personal injury Before attempting to operate the machine it is essential that you read this manu...

Страница 5: ...are also live when power is on In semiautomatic or automatic wire welding the wire wire reel drive roll housing and all metal parts touching the welding wire are electrically live Incorrectly installe...

Страница 6: ...rth currents safely Equipment made electrically LIVE by stray current may shock possibly fatally Do NOT EARTH to electrical conduit or to a pipe carrying ANY gas or a flammable liquid such as oil or f...

Страница 7: ...ne particulate material The fume is mostly oxides of the metals including any alloying elements but it also contains gases produced in the arc such as ozone or oxides of nitrogen and decomposition pro...

Страница 8: ...ut Move the work if practicable to an area free of combustibles Avoid paint spray rooms dip tanks storage areas ventilators If the work cannot be moved move combustibles at least 10M away out of reach...

Страница 9: ...ammables within 35 ft 10 7 m of the welding arc If this is not possible tightly cover them with approved covers 4 Be alert that welding sparks and hot materials from welding can easily go through smal...

Страница 10: ...Lift unit with handle on top of case 2 Use handcart or similar device of adequate capacity 3 If using a fork lift vehicle place and secure unit on a proper skid before transporting Optical Radiation T...

Страница 11: ...SAFETY INFORMATION 10...

Страница 12: ...EMF fields from the welding circuit 5 Route the electrode and work cables together Secure them with tape when possible 6 Never coil the electrode lead around your body 7 Do not place your body between...

Страница 13: ...terials from the work area Ensure adequate ventilation in areas where welding is being performed Do not weld on containers or pipes that hold or have held flammable liquid or gases danger of explosion...

Страница 14: ...at any person or animal 18 NEVER touch the torch nozzle until the welder is switched OFF and the nozzle has been allowed to cool off 19 NEVER connect disconnect or attempt to service the torch until t...

Страница 15: ...create sparks which may ignite the dust or fumes c Keep children and bystanders away while operating a power tool Distractions can cause you to lose control 2 Electrical Safety a Power tool plugs must...

Страница 16: ...be controlled with the switch is dangerous and must be repaired c Disconnect the plug from the power source before making any adjustments changing accessories or storing power tools Such preventive sa...

Страница 17: ...the machine away from radio controlled machinery Normal operation may adversely affect the operation of nearby radio controlled machinery which may result in injury or equipment damage Read the sectio...

Страница 18: ...g Flexible metallic conduit is generally not suitable 8 When the welder is enclosed in a metal building several earth driven electrical grounds connected as in 5b above around the periphery of the bui...

Страница 19: ...acement fuse covers can be obtained from your local dealer or most electrical stockists Fuse Rating The fuse in the plug must be replaced with one of the same rating 13 amps and this replacement must...

Страница 20: ...VRD On Off button 12 MMA TIG selector button 13 Earth clamp attachment point Technical specification Input power 230V 50Hz Phase 1 Rated input current 29 2A Electrode size 1 6 3 2mm Rated no load vol...

Страница 21: ...o not let children play with empty plastic bags due to the risk of suffocation MMA ASSEMBLY ELECTRIC SHOCK can kill Keep the electrode holder and cable insulation in good condition Do not touch electr...

Страница 22: ...recommend you seek training from an experienced person CAUTION This manual is a basic guide to welding We recommend you purchase a good quality publication on welding or if you have internet access vi...

Страница 23: ...ower supply until you are ready to start welding Practice welding on a piece of scrap material Voltage Reduction Device A voltage reduction device VRD is a hazard reduction device that lowers the weld...

Страница 24: ...your hand Be sure the insulation on your cable and electrode holder is not faulty otherwise you are risking an electric shock StrikingThe Arc Holding a face mask in front of your face stroke the elec...

Страница 25: ...away At the same time the electrode has to move along the plate to form a bead The electrode is directed at the weld pool at about 20 from the vertical The rate of travel has to be adjusted so that a...

Страница 26: ...ne Rutile Electrodes contain a high proportion of titanium oxide rutile in the coating Titanium oxide promotes easy arc ignition smooth arc operation and low spatter These electrodes are general purpo...

Страница 27: ...rather that warm Under these conditions and in original packaging electrode storage time is practically unlimited It should be noted that electrodes are now available in hermetically sealed packs whi...

Страница 28: ...an no longer be cleaned it will need to be replaced Unscrew the nozzle and replace it with a new one Always try to avoid getting particles of metal inside the machine since they could cause short circ...

Страница 29: ...on does not allow correct electrode angle Electrode too large for joint Insufficient deposit time at edge of weave Reduce the control knob until welding current is reasonably constant while prohibitin...

Страница 30: ...roat thickness Weld current is too high Improper welding polarity Long Arc Length Weld current is too high Use larger electrodes and preheat the plate Increase welding current Adjust angle so the weld...

Страница 31: ...ting E 3 message is displayed on the digital display The rated current of the electrode holder is smaller than its actual working current No input power Replace it Check if any loose contact exists in...

Страница 32: ...t Disposing of this product correctly will help to save valuable resources and prevent any potential adverse effects on human health and the environment which could otherwise arise from inappropriate...

Страница 33: ...rodes 50Hz Nominal mains frequency Diameter of electrodes U0 No load voltage A V to A V Range of output X Duty cycle I2 Conventional welding current U2 Conventional load voltage U1 Mains voltage I1 ma...

Страница 34: ...facilities exist Check with your Local Authority or retailer for recycling advice Warning Electrical welding process uV Protect operator and passer bye from the effect of uV radiation This can cause...

Страница 35: ...34 WIRING DIAGRAM...

Страница 36: ...e relevant harmonised standards used or references to the other technical specifications in relation to which conformity is declared 7 The person authorized to compile the technical file Name S rgio F...

Отзывы: