© Adam Equipment Company 2004
11
•
The limits are displayed in Kg.
•
Pressing the [Zero/Enter] key will return the scale to weighing,
with the Check-weighing function enabled.
•
When a weight is placed on the scale the arrows will show
whether the weight is above or below the limits and the beeper
will sound as described below.
BOTH LIMITS SET
The display will show OK and the beeper will
sound when the weight is between the limits.
LOW LIMIT SET
HIGH LIMIT is set to zero.
The display will show OK and the beeper will
sound when the weight is less than the Low
Limit. Above the Low Limit the display will
show HI and the beeper will be off.
HIGH LIMIT SET
LOW LIMIT is set to zero.
The display will show LO and the beeper will
be off when the weight is less than the High
Limit. Above the High Limit the display will
show OK and the beeper will be on.
BOTH LIMITS SET.
LOW IS SET
GREATER THAN
HIGH
The beeper will never sound and the display
will show LO if the weight is less that the Low
Limit and HI if the weight is greater than the
Low Limit.
6.6.2 Setting up Checkweighing while Parts Counting
•
Checkweighing facility can be set up for Parts Counting by
entering values as Low and High Limits to be keyed in by the
user. The limits are displayed in PCS.
•
Press [Func] to enter the Parts Counting mode. Press
[Zero/Enter] to fix a sample size. Press [Limit] and enter the
numeric values for high and low limits following the same
procedure as stated in the earlier section.
NOTE:
•
The weight must be greater than 20 scale divisions for the check-
weighing to operate.
•
To disable the Checkweighing function, enter zero into both limits
by pressing [Limit/ ] to recall the current settings.
Содержание BA114