3.4

 

ELECTRICAL SPECIFICATIONS  

3.4.1

 

CURRENT, VOLTAGE AND POWER RATINGS 

Electrical ratings

Pump Rated 

voltage

P

min

[W]

P

max

[W]

I

min

 [A] 

 I

max

[A]

NMT Mini XX/30 

230 VAC ± 15 %, 47-63Hz 

Pumps can operate at 

reduced voltage with limited 

power (P=Imax*U) 

15

0,05 

NMT Mini XX/40 

20

NMT Mini XX/60 

35

NMT Mini XX/80 

50

4

 

PUMP INSTALLATION  

4.1

 

INSTALLATION INTO PIPE LINES 

The arrows on the hydraulic casing and thermal insulation indicate the direction of the medium flow. For the 
pump to operate with minimal vibrations and noise it should be installed into pipe lines with its 1-1 axis in 
horizontal position, as showed in . Pipes should be without curves for at least 5-10 D (D = rated pipe diameter) 
from the first curve.

 

Desired head orientation can be achieved by rotating the pump head (allowed positions shown in figure figure 
1. Pump head is mounted on the hydraulic casting with four screws. The pump head can be turned by unscrewing 
the four screws (figure 3). When reassembling care should be taken to ensure seal fit. Failing to ensure seal fit 
could cause leaking of water into and damage to internal pump parts.  

Pump ambient should be dry and well lit. The pump is sealed from dust and water according to its 
ip class. 

 

 

Misconnection or overload could cause pump shutdown or even permanent damage. 

 

The pump doesn't have a ventilation screw. It is ventilated together with the system. Air in 
the pump can cause noise, which will disappear after a short working period. 

 

 

Pump must not be used in the safety pipelines,

 

Glands must be tightly screwed, 

 

When used in climate systems remove thermal insulation from pump, 

 

The pump should not be used as a handle for welding the pipe system, since it can be 
damaged, 

 

 If the gasket between the electro-motor part of the pump and the console is not correctly 
installed, the pump will not be watertight and there is danger of damage to the pump, 

 

There are openings for condensate drain on the housing of the electric motor, these must 
remain free (must not be thermally insulated), as this may interfere with the cooling of the 
engine or the discharge of condensed water, figure 2, 

 

 

Medium temperature must be higher or the same as ambient temperature, so that the 
condensate doesn’t  gather on pump surfaces. 

 

 

Operation outside recommended conditions may shorten pump lifetime and could void the 
warranty. 

 

Operation at edge conditions can shorten pump lifespan. 

Содержание NMT Mini Series

Страница 1: ...NMT Mini 7340131 v1 Navodila za vgradnjo in uporabo Installation and operating manual Installations und Bedienungsanleitung SLO EN DE...

Страница 2: ...Electromagnetic compatibility EMC 2004 108 EC EN 55014 1 EN 55014 2 EN 61000 3 2 EN 61000 3 3 Ecodesign Directive 2009 125 EC Circulators Commission Regulation No 641 2009 EN 16297 1 2012 EN 16297 2 2...

Страница 3: ...radnja rpalke 7 4 1 Vgradnja v cevovod 7 4 2 Elektri ni priklop 7 5 Nastavitev in delovanje 8 5 1 Nadzor in funkcije 8 5 1 1 Zaslon 8 5 1 1 1 Osnovni zaslon 8 5 1 1 2 Napredni zaslon 9 5 1 2 Tipka 9 5...

Страница 4: ...h delov za ta izdelek je 7 let od dneva poteka garancije Ta izdelek in njegove dele je potrebno odstraniti na okolju prijazen na in Uporabite podjetja za odvoz odpadkov e pa to ni mogo e pa stopite v...

Страница 5: ...splozivnih medijev in v eksplozivni atmosferi rpalka je zaradi magnetnega rotorja nagnjena k nabiranju magnetnih delcev na rotorju in posledi no k abraziji le ajnih mest in prekatne pu e ali v skrajne...

Страница 6: ...aks A NMT Mini XX 30 230VAC 15 47 63Hz rpalke delujejo tudi pri manj i napetosti z zmanj ano mo jo P Imaks U 1 15 0 05 NMT Mini XX 40 20 NMT Mini XX 60 35 NMT Mini XX 80 50 Obratovanje izven priporo e...

Страница 7: ...ravli nim ohi jem ne bo pravilno name eno rpalka ne bo tesna in obstaja nevarnost po kodb rpalke Na stiku ohi ja elektromotorja in hidravli nega ohi ja se nahajajo odprtine za odvod kondenza te morajo...

Страница 8: ...ljo stopnja bosta svetila na in delovanja in stopnja V primeru da stopnje delovanja ni na voljo bo svetil samo na in delovanja 5 1 1 1 OSNOVNI ZASLON rpalke imajo mo nost delovanja med 3 predstavljeni...

Страница 9: ...Konstantna hitrost No ni re im Zaslon mo i tlaka in pretoka Prikaz stopnje delovanja Tretja stopnja oran na Druga stopnja zelena Prva stopnja modra Privzeti prikaz 5 1 2 TIPKA Kratek pritisk tipke pr...

Страница 10: ...lak talno ogrevanje rpalka vzdr uje trenutno nastavljen tlak 3 predstavljene stopnje od pretoka 0 do maksimalne mo i kjer se pri ne tlak zni evati Konstantni obrati hitrost rpalka s konstantnimi vrtlj...

Страница 11: ...okvare motorja ali pregosti medij 2 Aktivna za ita 22 Temperatura elektronike je previsoka Mo je zni ana na 2 3 nazivne mo i 23 Temperatura elektronike je previsoka rpalka se je ustavila 24 Prevelik t...

Страница 12: ...namek ni definiran 4 Pump installation Napaka Zaznamek ni definiran 4 1 installation into pipe lines Napaka Zaznamek ni definiran 4 2 Electrical connection Napaka Zaznamek ni definiran 5 Setup and ope...

Страница 13: ...TS AND DECOMMISSIONING Pumps have been designed to operate without maintenance for several years Spare parts will be available for at least 7 years from the warranty period expiration This product and...

Страница 14: ...sive media and in an explosive atmosphere Permanent magnet rotor inside the pump is prone to accumulating magnetic particles on its surface which can lead to abrasion of bearings and rotor can or even...

Страница 15: ...nal pump parts Pump ambient should be dry and well lit The pump is sealed from dust and water according to its ip class Misconnection or overload could cause pump shutdown or even permanent damage The...

Страница 16: ...Hot media poses a threat of burns The pump motor can reach a dangerous temperature which poses danger to health...

Страница 17: ...safety Pipe systems should be grounded separately Electrical connection of the pump should be conducted by trained and qualified personnel The cable connection must be done in a manner that ensures th...

Страница 18: ...curve is available then the pump curve and mode symbols will be lit In case that there is no pump curve available then only the symbol for pump mode will be lit 5 1 1 1 BASIC DISPLAY Pumps have 3 prec...

Страница 19: ...represents the selected mode and curve The pump also shows the current power consumption current pressure and flow Values on the display interchange every 5 s Pump modes Auto mode Proprotional pressu...

Страница 20: ...essure radiator heating The pump maintains the pressure with relation to the current flow The pressure is equal to the set pressure 3 preconfigured curves at maximum power at 0 flow it is equal to HQ...

Страница 21: ...ht be faulty or a viscous medium is present 2 Protection active 22 The circuit is too hot and the power was reduced to less than 2 3 of the rated power 23 The circuit is too hot to run and the pump ha...

Страница 22: ...stallation 25 4 1 Installation in der Rohrleitung 25 4 2 Elektrische Verbindung 26 5 Einsatz und Betrieb 27 5 1 Anzeigen und Funktionen 27 5 1 1 Display 27 5 1 1 1 Anzeige der Grundeinstellung 27 5 1...

Страница 23: ...nd Das Produkt und seine Komponenten m ssen umweltfreundlich entsorgt werden Nutzen Sie die Entsorgungsgesellschaft Ist dies nicht m glich den n chsten IMP Pumpen Service oder andere autorisierte Werk...

Страница 24: ...en Stoffen Frei sein von Mixen aus l und Feststoffen oder fasrigen Partikeln Die Pumpe darf nicht benutzt werden zum F rdern von brennbaren entz ndlichen Teilen und in explosiven R umlichkeiten 3 3 TE...

Страница 25: ...u l sen Gr e 4mm Das Umfeld der Pumpe sollte trocken sein und mit der Schutzklasse bereinstimmen Falschanschluss oder berlastung k nnen eine Abschaltung oder eine Besch digung herbeif hren Die Pumpe h...

Страница 26: ...als erstes angeschlossen werden Erdung ist f r die Pumpensicherheit von gro er Bedeutung Die Rohrleitung sollte separat geerdet werden Der elektrische Anschluss der Pumpe ist nur von einem Fachmann z...

Страница 27: ...n ver ndert werden durch dr cken auf das Pumpensymbol in der Mitte Wenn eine Pumpenstufe bekannt ist nutzen Sie diese 5 1 1 1 ANZEIGE DER GRUNDEINSTELLUNG Die Pumpe hat 3 vorkonfigurierte Betriebsarte...

Страница 28: ...die ausgew hlte Funktion Die Pumpe zeigt auch die elektrische Leistungsaufnahme die Pumpenf rderh he und den Durchfluss an Die Werte werden alle 5 Sekunden aktualisiert Pumpen Modus Automatik Modus P...

Страница 29: ...r Die Pumpe h lt den Druck in Abh ngigkeit vom Durchfluss Der eingestellte Druck ist der maximale Druckwert Sinkt der Durchfluss sinkt auch der Druck Bei 0 Durchfluss betr gt der Druck nur noch 60 vom...

Страница 30: ...otor berlast Der Motor k nnte defekt sein oder ein z hes Medium ist vorhanden 2 Aktiver Schutz 22 Das Modul ist hei Leistung auf 2 3 reduzieren 23 Das Modul wir zu hei Die Pumpe bleibt stehen 24 Hardw...

Страница 31: ...Figure 1 Figure 2...

Страница 32: ...Figure 3...

Страница 33: ...zdelka se prizna le v primeru e je bil izdelek dostavljen najbli jemu poobla enemu servisu ali prodajalcu do vi ine ki velja po veljavni elezni ki ali po tni tarifi Da bo v garancijskem roku opravil d...

Страница 34: ...only recognized if the product was delivered to the nearest authorized service or retailer and comprise rail or postal charges That within the term of guarantee work to maintain or repair the product...

Страница 35: ...en bis zu der H he die nach der g ltigen Post oder Bahngeb hr berechnet wird er innerhalb der Garantiezeit die Instandhaltungen oder Reparaturen am Produkt sp testens in 45 Tagen ab dem Tag an dem er...

Отзывы: