Slew Drives
Installation and commissioning
25
Permissible flatness and perpendicularity deviation for series WD-L and SP slew drives
Running circle diameter [mm]
≥100
≥250
≥500
≥750
≥1000
≥1250
[mm]
0.04
0.06
0.08
0.09
0.10
0.11
Permissible flatness deviation
including perpendicularity
deviation per support surface
[in]
0.0016
0.0024
0.0032
0.0036
0.0040
0.0044
Tab. 2
Permissible flatness and perpendicularity deviation for series WD-H slew drives
Size of the slew drive
≥146
≥220
≥300
≥373
≥490
≥625
[mm]
0.06
0.06
0.07
0.07
0.08
0.09
Permissible flatness deviation
including perpendicularity
deviation per support surface
[in]
0.0024
0.0024
0.0028
0.0028
0.0032
0.0036
Tab. 3
Determining the deformation of the mounting structure
Under maximum operating load an appropriate deformation of the
mounting structure occurs. The dimensions can be detected via
dial gauges, laser measurement processes, or 3D measuring
systems.
Because in some cases measurement in operation is difficult,
determination of deformation can also be executed
mathematically, e.g. with the finite element method.
Alternatively you can also reference comparable measurements on
test rigs.
For slew drives that are between the specified sizes, always
assume the smaller value. For slew drives that are larger than
the largest diameter, use the largest specified value.
The slew drive must be supported by the mounting structure up
to the diameter specified in the slew drive drawing. All the
installed dimensions as specified in the drawing must be
complied with.
Permissible deformation of the mounting structure, under maximum load for series WD-L and
SP slew drives
Running circle diameter [mm]
≥100
≥250
≥500
≥750
≥1000 ≥1250
[mm]
0.13
0.16
0.21
0.24
0.27
0.29
Permissible deformation of the
mounting structure per support
surface
[in]
0.0052
0.0063
0.0083
0.0095
0.0106
0.0114
Tab. 4
Permissible deformation of the mounting structure, under maximum load for series WD-H slew
drives
Size of the slew drive
≥146
≥220
≥300
≥373
≥490
≥625
[mm]
0.10
0.11
0.12
0.13
0.15
0.16
Permissible deformation of the
mounting structure per support
surface
[in]
0.0040
0.0044
0.0048
0.0052
0.0059
0.0063
Tab. 5