ImmersionRC RF Power meter Скачать руководство пользователя страница 4

 

 

ImmersionRC | ImmersionRC RF Power Meter 

 

The top button will decrement the frequency; the bottom button will increment it.  
The center button enters the menu, where the setup of the power meter 

 may be adjusted:  

Contrast

: LCD contrast, not normally necessary to change this, but it the display is difficult to read, it 

may help to adjust this.  

Mode

Peak

 or 

Avg, 

use Avg mode for a more precise reading of continuous RF sources, such as A/V 

transmitters. Use 

Peak

 for pulsed sources, such as UHF uplinks, or wireless networking equipment.  

Mode:

 

dBm

 or 

mW

. Measurement readout format.  

Attenuation

: Enter the attenuation, in dB, of any attached attenuator(s). For multiple stages of 

attenuation, enter the total attenuation (e.g. 10dB + 10dB = 20dB of attenuation).  
If calibration data for the attenuator is available, use the 

Fine Attenuation 

control also.  

 

NOTE: If the Pwr value is flashing, the measured power is outside of the power meter’s range, either too 
low, or too high. The former is just a warning that the displayed value is not accurate (and will occur 
when power is applied with no RF connection), the latter is a warning that the meter may be damaged.  

Firmware Upgrade 

If for any reason a firmware upgrade is needed, be sure to use a version of the ImmersionRC Tools later 
than March 2010 to upgrade.  

Using the correct version of this tool will ensure that the calibration curves, measured during testing, are 
preserved, and therefore the accuracy of the device is preserved also.  

It is highly recommended not to upgrade firmware in the power meter unless instructed to by 
ImmersionRC.  

 

 