background image

 

 

www.immersionrc.com 

 

[email protected] 

For example to change the Low Battery 100mV setting: 

Button pressed for > 5 seconds 

 

Dash Dot Dot   

- second menu item –    

press  button briefly to enter setting

 

Dot 

 

 

 

 

 

current setting (auto)

 

Dot 

 

 

- first available option -   

0.0v 

press button briefly 

Dot Dot  

 

- second available option -  

100mV 

press button briefly 

At this point the Low Battery 100mV setting has been changed to ‘100mV’. The module will now 
continue with the next item in the menu, and continue to the end of the list.  Once the end of the list is 
reached, the receiver will automatically exit the programming mode signaled by two short beeps. 

Beep Codes  

Beep Code 

Menu 

Menu Choices 

- . 

Low Batt Volts 

1 – Auto (for 2S or 3S LiPo)* 

2 – 6v 

3 – 7v 

4 – 8v 

5 – 9v  

6 –10v 

7 – 11v 

8 – 12v 

Default: 6V for 2S, 9V for 3S 

- . . 

Low Batt 100mV 

1 – 0.0v  …. 10 – 0.9v 

Default: 0.5v (for threshold of 9.5v) 

(Ignored in Auto mode) 

 
Note that * indicates the default value .

 