1.22 CONFIGURATION C10 - C12 SEPARATOR KIT (Ø 80/80)
C
10
32
C
12
33
This configuration (allowed only with the approved original flue), makes it possible to suck the air outside the home or directly from the
shaft where the flue gas exhaust is present and the evacuation of the flue gas itself inside a collective flue.
C10
(Fig. 32):
Coupling to the shaft for intake is possible with male flue Ø 80 or Ø 80 cut female.
C10 - C12
(Fig. 32 - 33)
The collective flue coupling for the exhaust is possible with female Ø 80 flue with gasket.
Mounting the separator kit Ø 80/80 (Fig. 34):
Install the discharge flange (4) on the boiler sample point flange, positioning the relative gasket (1) with the circular projections down-
wards in contact with the boiler flange, and tighten using the hex screws with flat tip contained in the kit.
1. Remove the extension Ø 125 from the non-return valve kit on the flue gas, insert the spacer Ø 80 th. 5 mm inside the flue gas exhaust
flange and then insert the non-return valve on the flue gas Ø 80.
2. Remove the flat flange present in the intake hole and replace it with the intake flange (3), positioning the gasket (2) contained in the
separator kit Ø 80/80 and tighten using the supplied self-threading screws.
3. Fit the bends with male side (smooth) (5) in the female side of the flanges (3 and 4).
4. For the intake from shaft (C10) or from a common intake duct, connect the Ø 80 intake ducts (6) to the bend (5), making sure to have
already inserted the internal wall sealing plate (7). For the wall intake (C12), fit the male end (smooth) of the intake terminal (6) into
the female end of the bend (5) up to the end stop, making sure to have already inserted the relative internal and external wall sealing
plate (7) (8).
Make sure to fill the flue gas non-return valve siphon with water
5. Connect the Ø 80 drain pipe making sure to have already inserted the internal wall sealing plate (7) inside the end section of the pipe.
For maximum extension of the Ø 80/80 terminals and for the installation dimensions, refer to the figures (Fig. 36 - 35)
For the development of the exhaust terminals, a maximum resistance of 19.5 is considered; to calculate the resistance factor,
refer to the tables on pages 21 and 22.