3.24 TECHNICAL DATA.
- The flue temperature values refer to an air inlet
temperature of 15
°
C and flow temperature of
50
°
C.
- The maximum sound level emitted during
boiler operation is
<
55dBA. The sound level
value is referred to semianechoic chamber tests
with the boiler operating at max. heat output,
with extension of the flue gas exhaust system
according to product standards.
- * When the boiler is connected to an external
storage tank unit.
Victrix 12X TT 2 ErP
Victrix 20X TT 2 ErP
Nominal heat input
kW (kcal/h)
12,3 (10575)
21,3 (18318)
Minimum heat input
kW (kcal/h)
1,9 (1667)
3,1 (2630)
Nominal heat output (useful)
kW (kcal/h)
12,0 (10320)
20,5 (17630)
Minimum heat output (useful)
kW (kcal/h)
1,9 (1634)
3,0 (2580)
** Efficiency 80/60 Nom./Min.
%
97,6 / 98,0
96,9 / 98,1
** Efficiency 50/30 Nom./Min.
%
105,4 / 108,0
101,2 / 108,6
** Efficiency 40/30 Nom./Min.
%
107,0 / 109,6
104,6 / 109,1
Casing losses with burner On/Off (80-60
°
C)
%
0,94 / 0,60
0,54 / 0,10
Heat loss at flue with burner On/Off (80-60
°
C)
%
0,02 / 1,8
0,01 / 3,0
Central heating circuit max. operating pressure
bar
3
3
Maximum heating temperature
°
C
90
90
Adjustable heating temperature (max operation field)
°
C
20 - 85
20 - 85
System expansion vessel total volume
l
5,8
5,8
Expansion vessel factory-set pressure
bar
1,0
1,0
Appliance water content
l
1,9
1,9
Head available with 1000 l/h flow rate
kPa (m H
2
O)
37,2 (3,8)
37,2 (3,8)
* Hot water production useful heat output
kW (kcal/h)
12,3 (10575)
21,3 (18308)
* Domestic hot water adjustable temperature
°
C
10 - 60
10 - 60
* Flow rate capacity in continuous duty (
∆
T 30
°
C)
l/min
-
12,2
Weight of full boiler
kg
33,9
33,9
Weight of empty boiler
kg
32,0
32,0
Electrical connection
V/Hz
230 / 50
230 / 50
Nominal power absorption
A
0,63
0,69
Installed electric power
W
90
90
Pump absorbed power
W
59
59
EEI
-
≤
0,20 - Part. 3
≤
0,20 - Part. 3
Fan power absorbed power
W
19
22
Equipment electrical system protection
-
IPX5D
IPX5D
Temperature of combustion products
°
C
75
75
NO
X
class
-
5
5
Weighted NO
X
mg/kWh
26,0
28,0
Weighted CO
mg/kWh
18,0
20,4
Type of appliance