1.10 BOILER COMMISSIONING 

(IGNITION).

In order to issue the Declaration of Conformity 

required by the regulations in force, one must 

comply with the following requirements to 

commission the boiler (the operations listed 

below must only be performed by qualified 

personnel and in the presence of staff only):

-  check that the internal system is properly sealed 

according to the regulations in force;

-  make sure that the type of gas used corresponds 

to boiler settings;

- check that there are no external factors that 

may cause the formation of fuel pockets;

-  switch the boiler on and check correct ignition;
- make sure that the gas flow rate and relevant 

pressure values comply with those given in the 

manual (par. 3.16);

- check the correct ventilation of the rooms;
- check the existing draught during normal 

functioning of the appliance, e.g. a draught 

gauge positioned at the exit of the appliance 

combustion products;

-  check that there is no backflow of combustion 

products into the room, even during 

functioning of fans;

- ensure that the safety device intervenes in the 

event of gas supply failure and check the relative 

intervention time;

- check activation of the main switch located 

upstream of the boiler.

The boiler must not be started up even if only 

one of the checks should be negative.

N.B.:

 the preliminary boiler check must be carried 

out by an authorised company. The standard boiler 

warranty is valid from the date of inspection.

The test certificate and warranty is issued to the 

user.

1.11 CIRCULATION PUMP.

The Nike Mythos 24 2E series boilers are 

supplied with a built-in circulation pump with 

three-position electric speed control. The boiler 

does not operate correctly with the circulation 

pump on first speed. To ensure optimal boiler 

operation, in the case of new systems (single 

pipe and module) it is recommended to use the 

pump at maximum speed. The circulation pump 

is already fitted with a capacitor.

Pump release.

 If, after a prolonged period of 

inactivity, the circulation pump is blocked, 

unscrew the front cap and turn the motor shaft 

using a screwdriver. Take great care during this 

operation to avoid damage to the motor.

By-pass regulation (part. 16 Fig. 1-6).

 If 

necessary, the by-pass can be adjusted according 

to system requirements from a minimum (by-

pass excluded) to a maximum (by-pass inserted) 

represented by the graph (Fig. 1-5). Make the 

adjustment using a flat head screwdriver, turn 

clockwise and insert the by-pass; by turning it 

anti-clockwise it is excluded.

1.12 KITS AVAILABLE ON REQUEST.

• Connection unit kit (on request). The kit 

includes pipes, fittings and cocks (including 

gas cock), to carry out all connections to the 

boiler system

•  System shut off valves kit. The boiler is designed 

for installation of system interception cocks 

to be placed on flow and return pipes of the 

connection assembly. This kit is particularly 

useful for maintenance as it allows to drain just 

the boiler without having to empty the entire 

system.

•  Polyphosphate dispenser kit. The polyphosphate 

dispenser reduces the formation of lime-scale 

and preserves the original heat exchange and 

domestic hot water production conditions. 

The boiler is prepared for application of the 

polyphosphate dispenser kit.

The above-mentioned kits are supplied complete 

with instructions for assembly and use.

Head available to the system.

  A  =  Head available to the system at maximum 

speed with by-pass excluded

  B  =  Head available to the system at maximum 

speed with by-pass inserted

  C  =  Head available to the system at second 

speed with by-pass excluded

  D  =  Head available to the system at second 

speed with by-pass inserted

H

ea

d (m H

2

O)

Flow rate (l/h)

H

ea

d (kP

a)

Fig. 1-5

Содержание NIKE MYTHOS 24 2 E

Страница 1: ...NIKE MYTHOS 24 2 E IE Instruction and warning book 1 038789ENG ...

Страница 2: ... technical information for installing Immergas boilers As for the other issues related to boiler installation e g safety in the work site environment protection injury prevention it is necessary to comply with the provisions specified in the regulations in force and principles of good practice In compliance with legislation in force the systems must be designed by qualified professionals within th...

Страница 3: ...ing 11 2 6 Restoring central heating system pressure 11 2 7 System draining 11 2 8 Anti freeze protection 12 2 9 Case cleaning 12 2 10 Decommissioning 12 3 Boiler commissioning initial check 13 3 1 Hydraulic diagram 13 3 2 Wiring diagram 14 3 3 Troubleshooting 14 3 4 Converting the boiler to other types of gas 15 3 5 Checks following conversion to another type of gas 15 3 6 Possible adjustments 15...

Страница 4: ...of malfunctions faults or incorrect operation turn the appliance off immediately and contact an authorised company e g the Immergas Technical Assistance centre which has specifically trained staff and original spare parts Do not attempt to modify or repair the appliance alone Failure to comply with the above implies personal responsibility and invalidates the warranty Installation regulations thes...

Страница 5: ... gas cock connection by following the mounting instructions illustrated in the figure The gas supply pipe must be suitably dimensioned according to current regulations in order to guarantee correct gas flow to the burnereveninconditionsofmaximumgenerator output and to guarantee appliance efficiency technical specifications The coupling system must conform to standards Fuel gas quality The applianc...

Страница 6: ... 1 4 REMOTE CONTROLS AND ROOM CHRONO THERMOSTATS OPTIONAL The boiler is prepared for the application of room chrono thermostats or remote controls which are available as optional kits Fig 1 4 All Immergas chrono thermostats are connected with 2 wires only Carefully read the user and assembly instructions contained in the accessory kit On Offdigitalchrono thermostat Thechrono thermostat allows set ...

Страница 7: ...responding to the top of the chimney flue independently of any caps must be out of the backflow area in order to prevent the formation of counter pressures that impede the free discharge of the combustion products into the atmosphere It is therefore necessary to use the minimum heights indicated in the figures stated in the regulation depending on the slope of the roof Direct exhaust outside The n...

Страница 8: ...p on first speed To ensure optimal boiler operation in the case of new systems single pipe and module it is recommended to use the pump at maximum speed The circulation pump is already fitted with a capacitor Pump release If after a prolonged period of inactivity the circulation pump is blocked unscrew the front cap and turn the motor shaft using a screwdriver Take great care during this operation...

Страница 9: ... 5 Gas valve 6 System filling valve 7 Flue safety thermostat 8 Primary heat exchanger 9 Delivery probe 10 Safety thermostat 11 Combustion chamber 12 Ignition and detection electrodes 13 System expansion vessel 14 Burner 15 Vent valve 16 By pass 17 DHW heat exchanger 18 Three way valve motorised 19 3 bar safety valve 20 System draining valve N B connection group optional ...

Страница 10: ... or other devices Never clean the appliance or connected parts with easily flammable substances Never leave containers or flammable substances in the same environment as the appliance It is prohibited and dangerous to obstruct the air intake even partially for the ventilation of the room in which the boiler is installed Due to the danger functioning is also prohibited in the same room as suction d...

Страница 11: ... hours code 03 it is necessary to reset the boiler manually by pressing the Reset button 1 If this anomaly persists contact a qualified technician for assistance e g Immergas After Sales Service Electro mechanical contacts This occurs when thesafetythermostat thefumepressureswitchor the system pressure switch do not work properly code 04 The boiler does not start try resetting the boiler If the an...

Страница 12: ... a prolonged absence the system must be drained completely or antifreeze substances must be added to the heating system water In both cases the boiler domestic hot wa ter circuit must be drained In systems that are drained frequently filling must be carried out with suitably treated water to eliminate hardness that can cause lime scale 2 9 CASE CLEANING Use damp cloths and neutral detergent to cle...

Страница 13: ...iance e g a draught gauge positioned at the exit of the appliance combustion products check that there is no backflow of combustion products into the room even during functioning of fans 3 1 HYDRAULIC DIAGRAM Fig 3 1 ensure activation of all adjustment devices seal the gas flow rate regulation devices if settings are modified check the production of domestic hot water check sealing efficiency of w...

Страница 14: ...ermostat It can depend on the lack of water in the boiler little water circulation in the system or blocked pump Check on the manometer that the system pressure is within established limits Check that the radiator valves are not closed and also the functionality of the pump The boiler produces condensate This can be caused by obstructions of the chimney or flues with height or section not proporti...

Страница 15: ...se direction the heating potential increases and in an anti clockwise direction it decreases Adjust the boiler minimum heat output in the domestic hot water phase Fig 3 3 N B only proceed after having calibrated the nominal pressure Adjustment of the minimum thermal input is obtained by operating on the cross plastic screws 2 on the gas valve maintaining the brass nut blocked 3 disconnect the powe...

Страница 16: ... boiler 2 monothermal boiler with boiler P9 3 8 AUTOMATIC SLOW IGNITION FUNCTION WITH TIMED RAMP DELIVERY In the ignition phase the P C B carries out an increasing gas delivery ramp with pressure values that depend on the type of gas selected with preset duration This prevents every calibration or precision adjustment of the boiler ignition phase in any conditions of use 3 9 CHIMNEY SWEEP FUNCTION...

Страница 17: ...ing can be completely removed as follows Fig 3 4 remove the frame 1 holding the edges and pulling it towards you as indicated by the arrows undo the 2 front screws 2 and the 2 lower screws 3 which fasten the casing 4 pull the casing 4 towards yourself and upwards at the same time in order to detach it from the upper hooks ...

Страница 18: ... be inside the fairleads there must be no traces of blackening or burning N B when performing periodical maintenance of the appliance it is also good practice to check and perform maintenance on the heating system in compliance with that indicated by the regulations in force N B gas flow rates refer to heating power below a temperature of 15 C and pressure of 1013 mbar Burner pressure values refer...

Страница 19: ...justable central heating temperature C 38 85 System expansion vessel total volume l 4 2 Expansion vessel factory set pressure bar 1 Water content in generator l 1 9 Head available with 1000 l h flow rate kPa m H2 O 24 5 2 5 Hot water production useful heat output kW kcal h 23 6 20296 Domestic hot water adjustable temperature C 30 38 60 77 Domestic hot water circuit flow limiter at 2 bar l min 7 7 ...

Страница 20: ...ode Sr N Serial Number CHK Check Cod PIN PIN code Type Type of installation ref CEN TR 1749 Qnw min Minimum heating capacity domestic Qn min Minimum heating capacity heating Qnw max Maximum heating capacity domestic Qn max Maximum heating capacity heating Pn min Minimum heat output Pn max Maximum heat output PMS Maximum pressure system PMW Maximum pressure domestic D Specific flow rate TM Maximum ...

Страница 21: ......

Страница 22: ......

Страница 23: ......

Страница 24: ...immergas com Immergas S p A 42041 Brescello RE Italy Tel 0522 689011 Fax 0522 680617 Certified company ISO 9001 This instruction booklet is made of ecological paper Cod 1 038789ENG rev ST 002138 000 07 15 Inglese per IRLANDA IE ...

Отзывы: