  INSTRUCTIONS FOR USE 

AND MAINTENANCE

2.1  CLEANING AND MAINTENANCE.

Attention:

 the heating systems must undergo 

periodical maintenance (regarding this, see 

the section dedicated to the maintenance 

engineer, relating to “yearly appliance check 

and maintenance”) and regular energy efficiency 

checks in compliance with national, regional or 

local provisions in force.

This ensures that the optimal safety, performance 

and operation characteristics of the boiler remain 

unchanged over time.

We recommend stipulating a yearly cleaning and 

maintenance contract with your zone technician.

2.2  VENTILATION OF THE ROOMS.

In the room in which the boiler is installed it 

is necessary that at least as much air flows as 

that requested for by normal combustion of the 

gas and ventilation of the room. The provisions 

relative to ventilation, the flue ducts, chimneys 

and caps are stated in Par. 1.6, 1.7 and 1.8. If 

in doubt regarding correct ventilation, refer to 

professional, qualified staff.

2.3  GENERAL WARNINGS.

Never expose the wall-mounted boiler to direct 

vapours from a cooking surface.

Use of the boiler by unskilled persons or children 

is strictly prohibited.

If temporary shutdown of the boiler is required, 

proceed as follows:

a)  drain the heating system if anti-freeze is not 

used;

b)  shut-off all electrical, water and gas supplies.
In the case of work or maintenance to structures 

located in the vicinity of ducting or devices 

for flue extraction and relative accessories, 

switch off the appliance and on completion of 

operations ensure that a qualified technician 

checks efficiency of the ducting or other devices.

Never clean the appliance or connected parts 

with easily flammable substances.

Never leave containers or flammable substances 

in the same environment as the appliance.

It is prohibited and dangerous to obstruct the air 

intake, even partially, for the ventilation of the 

room in which the boiler is installed.

Due to the danger, functioning is also prohibited 

in the same room as suction devices, chimneys 

or similar at the same time as the boiler unless 

there are additional openings dimensioned in a 

way to satisfy the further necessity for air. For the 

dimensioning of these additional openings, refer 

to qualified technical staff. In particular, an open 

fire must have its own air supply.

On the contrary, the boiler cannot be installed 

in the same room.

• 

Attenzione:

 the use of components involving 

use of electrical power requires some 

fundamental rules to be observed:

  - do not touch the appliance with wet or 

moist parts of the body; do not touch when 

barefoot;

  - never pull electrical cables or leave the 

appliance exposed to weathering (rain, 

sunlight, etc.);

  - the appliance power cable must not be 

replaced by the user;

  - in the event of damage to the cable, switch 

off the appliance and contact exclusively 

qualified staff for replacement;

  -  if the appliance is not to be used for a certain 

period, disconnect the main power switch.

2.4  CONTROL PANEL.

Fig. 2-1

Key:

  1  -  Flame presence LED

  2  -  Domestic hot water LED

  3  -  Heating LED

  4  -  Temperature LED – Insufficient circulation anomaly

  5  -  Temperature LED – Flow probe anomaly

  6  -  Temperature LED – Ignition block anomaly

  7  -  Temperature LED – Overheating block

  8  -  Temperature LED - Flue gas pressure switch block

  9  -  Stand-by-Domestic water / Remote Control - Domestic water 

and Heating-Reset Selector

  10  -  Domestic hot water temperature selector

  11  -  Central heating temperature selector

  12  -  Boiler pressure gauge

Содержание NIKE MINI 28 KW SPECIAL

Страница 1: ...NIKE MINI 28 KW SPECIAL Instruction and warning booklet IE 1 038788ENG ...

Страница 2: ... technical information for installing Immergas boilers As for the other issues related to boiler installation e g safety in the work site environment protection injury prevention it is necessary to comply with the provisions specified in the regulations in force and principles of good practice In compliance with legislation in force the systems must be designed by qualified professionals within th...

Страница 3: ...al heating system pressure 12 2 9 System draining 12 2 10 Anti freeze protection 12 2 11 Case cleaning 12 2 12 Decommissioning 12 3 Boiler start up initial check 13 3 1 Hydraulic diagram 13 3 2 Wiring diagram 14 3 3 Troubleshooting 14 3 4 Converting the boiler to other types of gas 15 3 5 Checks following conversion to another type of gas 15 3 6 Possible adjustments of the gas valve 15 3 7 Program...

Страница 4: ...ates the warranty Installation regulations theseboilerscannotbeinstalledinbedrooms studio flats and bathrooms They also cannot be installed in rooms with wood or solid fuel burning heat generators and in adjacent and communicating rooms Installation in places with a fire risk is prohibited for example garages closed parkingstalls gasappliancesandrelativeflue ducts flue exhaust pipes and combustion...

Страница 5: ...e type used in the boiler which must comply with the regulations in force as insufficient levels can reduce generator output and cause malfunctions Ensure correct gas cock connection by following the mounting instructions illustrated in the figure The gas supply pipe must be suitably dimensioned according to current regulations in order to guarantee correct gas flow to the burnereveninconditionsof...

Страница 6: ...ergas chrono thermostats are connected with 2 wires only Carefully read the user and assembly instructions contained in the accessory kit On Offdigitalchrono thermostat Thechrono thermostat allows set two room temperature value one for daytime comfort temperature and one for nighttime lower temperature set a weekly programme with four daily switch on and switch off times select the required operat...

Страница 7: ... dangerous situations for the user The flue ducts must be connected to the chimney or flue in the same room in which the appliance is installed or at most in the adjoining room and must comply with the requirements indicated by the regulation 1 8 FLUES CHIMNEYS For the appliances with natural draught individual chimneys and branched flues can be used Individual chimneys The individual flues must b...

Страница 8: ...supplyfailureandchecktherelative intervention time check activation of the main switch located upstream of the boiler The boiler must not be started up even if only one of the checks should be negative N B The preliminary boiler check must be carried out by a qualified technician The standard boiler warranty is valid from the date of inspection The test certificate and warranty is issued to the us...

Страница 9: ...ety thermostat 6 Fumes hood 7 Delivery probe 8 Safety thermostat 9 System expansion vessel 10 Combustion chamber 11 Boiler circulator pump 12 3 bar safety valve 13 Automatic by pass 14 Three way valve motorised 15 System draining valve 16 Primary heat exchanger 17 Ignition and detection electrodes 18 Vent valve 19 DHW heat exchanger N B connection group optional ...

Страница 10: ... other devices Never clean the appliance or connected parts with easily flammable substances Never leave containers or flammable substances in the same environment as the appliance It is prohibited and dangerous to obstruct the air intake even partially for the ventilation of the room in which the boiler is installed Due to the danger functioning is also prohibited in the same room as suction devi...

Страница 11: ...and 7 flash at the same time 04 Parasite flame block LEDs 1 and 7 flash at the same time 20 Loss of remote control communication LEDs 2 and 3 flash alternately 31 Insufficient water circulation This occurs if there is overheating in the boiler due to insufficient water circulating in the primary circuit the causes can be low system circulation check that no shut off devices are closed on the heati...

Страница 12: ...rmal pressure via the valve located at the bottom of the boiler Fig 2 2 N B close the valve after the operation If pressure values reach around 3 bar the safety valve may be activated In this case contact a professional technician for assistance In the event of frequent pressure drops contact qualified staff for assistance to eliminate the possible system leakage 2 9 SYSTEM DRAINING To drain the b...

Страница 13: ...he appliance e g a draught gauge positioned at the exit of the appliance combustion products check that there is no backflow of combustion products into the room even during functioning of fans ensure activation of all adjustment devices seal the gas flow rate regulation devices if settings are modified check the production of domestic hot water check sealing efficiency of water circuits check ven...

Страница 14: ...ect installation of the terminal Frequent interventions of the over heating safety thermostat It can depend on reduced water pressure in the boiler little circulation in the heating system the blocked pump or an anomaly of the boiler P C B Check on the pressure gauge that the system pressure is within established limits Check that radiator valves are not all closed The boiler produces condensate T...

Страница 15: ...operations must be carried out by a qualified technician e g Immergas After Sales Technical Assistance Service Burner adjustment must be carried out using a U or digital pressure gauge connected to the gas valve outlet pressure point Part 4 Fig 3 3 keeping to the pressure value provided in the tables Par 3 16 according to the type of gas for which the boiler is prepared Fig 3 3 P C B SIT 845 GAS V...

Страница 16: ... tables Heating output The boiler is produced and calibrated in the central heating phase at nominal output Permanent reduction of the timer The boiler has an electronic timing device that prevents the burner from igniting too often in the heating phase The boiler has a standard supply of a timer adjusted at 180 seconds Heating switch on timer continuous variation Flashing LED slow 30 seconds LED ...

Страница 17: ...r with boiler in standby the function activates every 18 hours after the last boiler check power supply In case of functioning in domestic hot water mode the self check starts within 10 minutes after the end of the withdrawing in progress for duration of approx 10 seconds N B during self check the boiler remains off including signalling 3 14 YEARLY APPLIANCE CHECK AND MAINTENANCE The following che...

Страница 18: ...panel 4 towards you taking care to remove the 2 fixing screws 5 3 16 HEAT OUTPUT N B gasflowratesrefertoheatingpowerbelowa temperature of 15 C and a pressure of 1013 mbar Burner pressure values refer to use of gas at 15 C METHANE G20 BUTANE G30 PROPANE G31 THERMAL POWER THERMAL POWER BURNER GAS FLOW RATE PRESS BURNER NOZZLES BURNER GAS FLOW RATE PRESS BURNER NOZZLES BURNER GAS FLOW RATE PRESS BURN...

Страница 19: ...ic hot water circuit flow limiter at 2 bar l min 9 3 Domestic circuit min pressure dynamic bar 0 3 Domestic hot water circuit max working pressure bar 10 Minimum D H W flow rate l min 1 5 Specific flow rate T 30 C l min 12 8 Flow rate capacity in continuous duty T 30 C l min 13 2 Weight of full boiler kg 33 9 Weight of empty boiler kg 31 0 Electrical connection V Hz 230 50 Nominal absorption A 0 4...

Страница 20: ...d Model Cod Md Model code Sr N Serial Number CHK Check Cod PIN PIN code Type Type of installation ref CEN TR 1749 Qnw min Minimum DHW heat input Qn min CH minimum heat input Qnw max DHW maximum heat input Qn max CH maximum heat input Pn min Minimum heat output Pn max Maximum heat output PMS Maximum system pressure PMW Maximum domestic hot water pressure D Specific flow rate TM Maximum operating te...

Страница 21: ......

Страница 22: ......

Страница 23: ......

Страница 24: ... immergas com Immergas S p A 42041 Brescello RE Italy Tel 0522 689011 Fax 0522 680617 Certified company ISO 9001 This instruction booklet is made of ecological paper Cod 1 038788ENG rev 002114 000 07 15 Inglese per IRLANDA IE ...

Отзывы: