1.12 CONCENTRIC VERTICAL KIT
INSTALLATION.
Type C configuration, sealed chamber and
fan assisted.
Concentric vertical intake and exhaust kit. This
vertical terminal is connected directly to the out-
side of the building for air intake and flue exhaust.
N.B.:
the vertical kit with aluminium tile enables
installation on terraces and roofs with a maxi-
mum slope of 45% (approx 25°) and the height
between the terminal cap and half-shell (374 mm
for Ø 60/100 and 260 mm for Ø 80/125) must
always be observed.
Vertical kit with aluminium tile Ø 60/100.
Kit assembly (Fig. 1-17): install the concentric
flange (2) on the central hole of the boiler, posi-
tioning gasket (1) with the circular projections
downwards in contact with the boiler flange, and
tighten using the screws contained in the kit.
Installation of the fake aluminium tile: replace
the tiles with the aluminium sheet (4), shaping
it to ensure that rainwater runs off. Position
the fixed half-shell (6) on the aluminium tile
and insert the intake-exhaust pipe (5). Fit the
Ø 60/100 (3) concentric terminal pipe with the
male side (5) (smooth) into the flange (2) up to
the end stop; making sure that the wall sealing
plate has been fitted (3), this will ensure sealing
and joining of the elements making up the kit.
• Extensions for vertical kit Ø 60/100 (Fig.
1-18). The kit with this configuration can be
extended to
a max. straight vertical length of 4,7
m
, including the terminal. This configuration
corresponds to a resistance factor of 100. In this
case specific extensions must be requested.
Vertical kit with aluminium tile Ø 80/125.
Kit assembly (Fig. 1-19): to install the kit Ø
80/125 one must use the flanged adapter kit in
order to install the flue system Ø 80/125. Install
the flanged adaptor (2) on the central hole of the
boiler, positioning gasket (1) with the circular
projections downwards in contact with the boiler
flange and tighten using the screws contained
in the kit. Installation of the fake aluminium
tile: replace the tiles with the aluminium sheet
(4), shaping it to ensure that rainwater runs off.
Position the fixed half-shell (5) on the aluminium
tile and insert the intake-exhaust pipe (7). Fit the
Ø 80/125 concentric terminal pipe with the male
side (smooth) to the female side of the adapter (1)
(with lip gaskets) up to the end stop; making sure
that the wall sealing plate (3) has been fitted, this
will ensure sealing and joining of the elements
making up the kit.
• Extensions for vertical kit Ø 80/125 (Fig. 1-20).
The kit with this configuration can be extended
up to a
max. length of 12,2 m
including the ter-
minal. If additional components are assembled,
the length equivalent to the maximum allowed
must be subtracted. In this case specific exten-
sions must be requested.
MAX
45%
MAXIMU
M LEN
GTH 12200 mm
MAX
45%
MAXIMU
M LEN
GTH 4700 mm
The fixing plate kit includes:
N° 1 - Gasket (1)
N° 1 - Female concentric flange (2)
The vertical kit includes:
N° 1 - Int./exhaust concentric pipe 0
60/100 (3)
N° 1 - Wall sealing plate (4)
N° 1 - Aluminium tile (5)
N° 1 - Fixed half-shell (6)
N° 1 - Mobile half-shell (7)
The kit includes:
N° 1 - Gasket (1)
N° 1 - Female concentric flange
(2)
N° 1 - Adapter
Ø 80/125 (3)
N° 1 - Int./exhaust concentric
pipe 0 80/125 (4)
N° 1 - Wall sealing plate (5)
N° 1 - Aluminium tile (6)
N° 1 - Fixed half-shell (7)
N° 1 - Mobile half-shell (8)
STD.002998/004
Содержание MAIOR EOLO 24
Страница 1: ...MAIOR EOLO 24 28 32 Instruction and recommendation booklet 1 038763ENG STD 002998 004 ...
Страница 2: ...STD 002998 004 ...
Страница 31: ...31 3 5 6 6 7 8 8 f f e INSTALLER USER MAINTENANCE TECHNICIAN STD 002998 004 ...
Страница 37: ...37 STD 002998 004 ...
Страница 38: ...38 STD 002998 004 ...
Страница 39: ...39 STD 002998 004 ...